HT98R068-1 Two-way Radio OTP MCU
Change Scrambling Code Inversion Frequency (3200Hz) Flow
Flow description:
<82C00>: Setup data: 00h. 2Ch [7] = 0 disable the scrambler.
<14082>: The CLI wrote ID code. To execute a write operation with the CLI Command,
it is necessary to execute this command first. No data response will be provided.
<1013A>: Select the 013A register. Setup it as a write register. No data response will
be provided.
<19873>: Setup data: 9873h. Write data to the register. A data response of 14000
means that it is correctly written; otherwise it means that no data has been correctly
written.
<14082>: The CLI wrote ID code. To execute a write operation with the CLI Command,
it is necessary to execute this command first. No data response will be provided.
<1013B>: Select the 013B register. Setup it as a write register. No data response will
be provided.
<14B3E>: Setup data: 4B3Eh. Write data to the register. A data response of 14000
means that it is correctly written; otherwise it means that no data has been correctly
written.
<82C80>: Setup data: 80h. 2Ch [7] = 1 enable the srambler.
33