Instructions for C-2000 Controller
Operation Instructions for C-2000B Controller
ANSWER A CALL FROM DOORBOX
When the phones ring, pick up a phone to be connected to the visitor
.
PLACING CO LINE CALLS ON HOLD (CALL WAITING)
If a phone call is in progress, and a doorbox is activated, one to four beeps will be heard (indicating which doorphone is calling).To place the call in progress on hold and
speak to the visitor, push
#
. When you want to return to the original phone call, push
#.
ACTIVATING A DOORSTRIKE OR OPENING A GATE
When a call is in progress, press to open the gate and return to the original call. If you do not want to open the gate, press
#
to return to the original call.
Strike can be activated with out the need of a “call-first” to the entry phone. Refer to the list below for codes for specific entry relays.
**
1
Move DIP switch 2 from OFF to ON position.
2
Come off-hook with any house phone connected to terminals 4 & 5
LINE OUT TO PHONES
.
3
Double beep indicates accessing the programming mode.
4
You can now program the C-2000A. The features covered in this manual are
Maximum Doorphone Ring Count
and
Door Strike Activation Time
. For information on programming other features see the Viking C-2000 manual.
5
Move DIP switch 2 back to the
OFF
position.
STEP
ACTION
Access Programming Mode (Local Access)
1
Follow steps 1-3 from “
Access Programming Mode
” (above).
2
At “double beep” enter desired number of rings, followed by #61. Example: For 7 rings, enter “07#61”.
3
Hang up the phone.
STEP
ACTION
Maximum Doorphone Ring Count - Factory Default is 5 Rings
1
Follow steps 1-3 from “
Access Programming Mode
” (above).
2
At “double beep” enter desired number of seconds of strike activation, followed by:
#19 for Gate 1, #29 for Gate 2, #39 for Gate 3, #49 for Gate 4
Examples:
Set Gate 1 for 8 seconds (08#19); Set Gate 3 for 15 seconds (15#39)
3
Hang up the phone.
STEP
ACTION
Program Gate Strike Relays - Factory Default is 0.5 Seconds
Entry Relay
Strike Code
1
#1**
2
#2**
3
#3**
4
#4**
The C-2000 controller is factory set to work right out of the box. If customization of
the default settings is required, see the steps listed below. Refer to the C-2000
manual for additional options
Page 5