Instructions for E-10 and E-40 Doorphones
In certain noisy locations (traffic or wind), the microphone volume may need to be decreased. A symptom of this is one-way talk path, in which the distant party
cannot be heard over the speaker. A “
MIC VOL
” adjustment is provided on the doorphone for increasing or decreasing the microphone volume.
Microphone Volume
DIP
Position
Description
Switch
1
ON
Auto Answer - Doorphone answers when incoming call is detected.
2
ON
Call Timer - See E-10 manual for a description of this feature. Recommended setting is “ON”. This is the factory default.
3
OFF
Programming Mode - E-10 is factory pre-set, and normally does not need re-programming. Refer to E-10 manual
(Viking document which is included) for details
O
N
O
N
O
N
1
2
3
O
N O
N O
N
1
2
3
+
+
Spkr Vol
Mic Vol
Holovision recommends the default settings on the dip switches. See the E-10 or E-40 manual for more information.
The “
SPKR VOL
” pot can be adjusted to increase or decrease the speaker volume to the desired level.
Speaker Volume
Dip Switch Settings
Doorphone Programming
Page 4
TYPE 6.5.0.3-RF
Instructions for C-2000B Controller
DIP
Position
Description
Switch
1 OFF Auxiliary Contact Mode
1 ON Doorbell Mode- Factory Default
2 OFF Normal Operation Mode- Factory Default
2 ON Security Code Bypass Mode
3 OFF Entry Phone automatic disconnect (CPC) disabled
3 ON Entry Phone automatic disconnect (CPC) enabled- Factory Default
4 OFF Entry Phone busy signal disabled
4 ON Entry Phone busy signal enabled- Factory Default
5 OFF Single Line Ring Through Mode- Factory Default
5 ON Analog Station Dial Through Mode
Dip Switch Settings C-2000B
ON