background image

Manual Type 1.1.0.3-RF

Viking E-10, C-2000B 

with Essex 265 Controller

For Models

Specifications

Communication

Viking E-10 Doorbox uses “half-duplex” 
communication, allowing for high speaker and
microphone volume, witout the possibility of 
feedback.
Viking C-2000A allows up to 4 doorphones to
share a CO line.

Access Control

Essex 5 button keypad
2 relays
5-6 users
16.5 VAC power supply included
Internal rectifier gives optional ‘’dc out’’ for strikes

INSTALLATION

INSTRUCTIONS

501 E. Goetz Ave.

Santa Ana, Ca 92707

www.eholovision.com

Ph. 714-434-6904

Fax 800-362-0002

HOLOVISION

101-VIK
107-VIK
201-VIK

203-VIK
301-VIK
302-VIK

Holovision Face Plate 

shown with E-10

installed

VIKING

c

Model C-2000B

1 2 3 4 5  6 7  8 9 10  11 12  13 14 15  16 17 18 19 20  21 22 23 24 25  26 27 28 29 30 31 32

E

A

R

T

H

 G

N

D

P

H

O

N

E

 L

IN

E

 I

N

P

U

T

LI

N

E

 O

U

T

 T

O

 P

H

O

N

E

S

E

N

T

R

Y

 P

H

O

N

E

 1

D

O

O

R

 S

T

R

IK

E

 1

E

N

T

R

Y

 P

H

O

N

E

 2

D

O

O

R

 S

T

R

IK

E

 2

E

N

T

R

Y

 P

H

O

N

E

 3

D

O

O

R

 S

T

R

IK

E

 3

E

N

T

R

Y

 P

H

O

N

E

 4

D

O

O

R

 S

T

R

IK

E

 4

D

O

O

R

B

E

LL

 S

W

IT

C

H

/A

U

X

 I

N

P

U

T

A

U

X

 C

O

N

TA

C

T

 O

U

T

P

U

T

1    2   3   4   5   6   7   8   9  10    11 12 13 14 15   16 17 18 19 20  21 22 23 24 25  26 27  28 29 30 31 32

O

N

 

   

   

  4

   

 5

 

A

N

A

LO

G

 S

TA

T

IO

N

 I

N

P

U

T

CONNECT CO LINE IN

13.8
VAC

1.25A

Содержание Viking C-2000B

Страница 1: ...ONS 501 E Goetz Ave Santa Ana Ca 92707 www eholovision com Ph 714 434 6904 Fax 800 362 0002 HOLOVISION 101 VIK 107 VIK 201 VIK 203 VIK 301 VIK 302 VIK Holovision Face Plate shown with E 10 installed V...

Страница 2: ...e 2 TYPE 1 1 0 3 RF VIKINGc Model C 2000B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 EARTH GND PHONE LINE INPUT LINE OUT TO PHONES ENTRY PHONE 1 DOOR STRIKE...

Страница 3: ...17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 EARTH GND PHONE LINE INPUT LINE OUT TO PHONES ENTRY PHONE 1 DOOR STRIKE 1 ENTRY PHONE 2 DOOR STRIKE 2 ENTRY PHONE 3 DOOR STRIKE 3 ENTRY PHONE 4 DOOR ST...

Страница 4: ...uded for details ON ON ON 1 2 3 ON ON ON 1 2 3 Spkr Vol Mic Vol Holovision recommends the default settings on the dip switches See the E 10 manual for more information E 10 The SPKR VOL pot can be adj...

Страница 5: ...ES 3 Double beep indicates accessing the programming mode 4 You can now program the C 2000A The features covered in this manual are Maximum Doorphone Ring Count and Door Strike Activation Time For inf...

Страница 6: ...5 Latch CCTV Doorbell Relay 1 Relay 2 Step Action 2 Relay 1 and 2 activate and latch Code Relay 1 Relay 2 Open Latch Open Latch Master Code No No No No Code 1 2 Yes Yes No No Code 3 4 5 No No Yes Yes...

Страница 7: ...conds of Step 3 5 Enter Master Code 6 Wait 5 seconds for 3 beeps to confirm new Master Code Set Master Code Step Action 1 Enter Master Code 2 Enter 111 3 beeps 3 Enter User Code 1 4 Wait 5 seconds for...

Страница 8: ...reset beeps 4 Wait 5 seconds for 3 reset beeps Delete Any Code Step Action Note User codes can be 3 to 8 digits 1 Enter any User Code 1 5 2 Enter 7 This will cause the relay to latch subject to the j...

Страница 9: ...ess Program switch keypad will beep 4 times 2 Enter 1115 3 beeps 3 Enter 1 for every 1 second latch time and 5 for every 5 seconds Examples 6 seconds 5 1 8 seconds 5 1 1 1 12 seconds 5 5 1 1 4 Wait 5...

Страница 10: ...www eholovision com 501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002...

Отзывы: