background image

  

IM-207-I 

 

HOLOPHANE

®

 Illuminaire

®

 / Illumibay

® 

Installation and 

 

The New Shape of Light

®

 Maintenance 

 

Integral Ballast Version 

Manual 

 

  

Manual 

AFTER INSTALLATION DELIVER THIS 

MANUAL TO OWNER

 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

WARNING

 

 

READ THESE INSTRUCTIONS 

CAREFULLY BEFORE ATTEMPTING TO INSTALL OR 
MAINTAIN THIS FIXTURE.  WORK MUST BE DONE BY 
QUALIFIED PERSONNEL. 

WARNING

 – BE CERTAIN THAT ALL ELECTRICAL 

POWER IS DISCONNECTED FROM THE FIXTURE 
BEFORE INSTALLING OR MAINTAINING THE FIXTURE. 

WARNING –

 FOLLOW LAMP MANUFACTURER’S 

OPERATING AND MAINTENANCE INSTRUCTIONS. 

 

FAILURE TO FOLLOW THESE WARNINGS MAY 

RESULT IN DEATH, INJURY OR SIGNIFICANT 

PROPERTY DAMAGE. 

 

 

  

 

 

GR1291 / GR1554 

 
1  INTRODUCTION 

 

1.1 Product Description

. The Illuminaire / Illumibay 

series lighting fixtures have been listed to 
applicable U.S. and Canadian safety standards 
by Underwriters Laboratories Inc. They are 
suitable for use in damp locations, and ambient 
temperatures to 40 degrees Celsius.

 

 
1.2  Alternate Information Sources

. If additional 

questions arise relative to this lighting fixture that this 
document or your supplier cannot answer, please 
refer them to :

 

Holophane 

Field Service Department 

P.O. Box 3004 

Newark, OH 43058-3004 

(866) 759-1577 

2  INSTALLATION

 

 

2.1  Tools and Materials Required

 

TABLE 1. Installation Tools and Materials 

DESCRIPTION USE 
Philips head screwdriver 

Electrical housing cap 

Socket and wrench set 

Optical hanging bolt & 

 Electrical 

disassembly 

Allen wrench set 

 

Optical set screw 

 

WARNING:

 

DO NOT SUSPEND THE LUMINAIRE SOLEY FROM A  

OUTLET BOX. THE LUMINAIRE WEIGHT EXCEEDS 

THE 50# CAPACITY OF OUTLET BOXES. FAILURE TO 

PROVIDE ADDITIONAL SUPPORT MAY RESULT IN 

INJURY OR DEATH OR SIGNIFICANT PROPERTY 

DAMAGE. 

 

 

2.2  Electrical Assembly Installation

 

 

SEE FIGURE 1

 

 

2.2.1

 Loosen two screws holding electrical housing 

cap in place. Rotate and lift off. 
 

PF Option or other hanging device

2.2.2 

Slip hanging device or PF through center hole 

of electrical housing cap and apply 4-5 drops of the 
thread locking liquid (provided) to threads of pipe and  
screw pipe in approximately ½ inch, this equals 7 
threads tightening securely. (Wipe away excess 
adhesive that may have squeezed out.)  

2.2.3 

Route wires through pipe to top of electrical 

housing and make wire connection in accordance 
with approved wiring methods. 

2.2.4

 Reinstall electrical housing cap and tighten 

screws. Tighten safety screw securely. 

2.2.5

 Hang the electrical housing to a secure location 

capable of withstanding 75 lbs. Tighten safety screw 
securley. 
 

2.3  Optical Assembly Installation. 

 

2.3.1 

Remove the

 

optical hanging bolt from parts bag 

located in the wiring area of the optical husk. It will 
self-thread into hole provided on top of the optical 
husk.  Tighten securely. 

2.3.2 

Lift optical and place optical hanging bolt in the 

slot provided for it in the electrical housing. This will 
provide a temporary means of hanging while the 
wiring connections are made. (See Fig. 1 Assembled 
View) 

Отзывы: