4. Repair/Replacement Instructions

Standard Optics ( 20º, 40º, and 60º)

The “non-user replaceable light source” must be serviced by  
Hunter-qualified personnel in a manner consistent with its in-
tended use and in compliance with all local and provincial codes. 
Unfasten faceplate and housing screws, using a ⅛

"

 (3.2 mm)

Allen wrench. Remove by lifting cap upward. Avoid using metal 
tools to protect the powder coat finish.

E0000

AAA

7/22/2012

REV

ECO

REVISION DESCRIPTION

DRFT

DATE

APVD

A

B

C

D

4

3

2

1

DIMENSIONAL

TOLERANCES:

REL.

DATE:

TITLE:

CHECKED

BY:

DESIGNER:

SCALE:

DRAWING NO.

REV.

PRINT

DATE:

UNLESS OTHERWISE SPECIFIED:

SURFACE FINISH:

ALL DIMENSIONS ARE IN INCHES

DO NOT SCALE DRAWING

1:2

BECKON, ASSEMBLY

DIS

21110495XXXX

N/A

ANGLES:

±1°

Hunter Industries

Engineering

1940 Diamond St.

San Marcos, CA 92078

C

D

A

B

4

3

2

1

SHEET  1  OF  1

.XX = ±.01

.XXX = ±.005

.XXXX = ±.0005

THIRD ANGLE PROJ.

C

SIZE:

5/11/2016

DRAWN

BY:

PRODUCT:

MATERIAL:

N/A

THIS DRAWING/DOCUMENT CONTAINS TRADE SECRET INFORMATION OF HUNT

ER INDUSTRIES, INC. USE, PUBLICATION, AND/OR 

DISCLOSURE OF THIS INFORMATION TO THIRD PARTIES ARE ALL PROHIBI

TED EXCEPT AS EXPRESSLY AUTHORIZED IN ADVANCE BY HUNTER. 

NO PATENT LICENSE IS GRANTED TO ANY INVENTIONS DESCRIBED AND/OR

 ILLUSTRATED HEREIN.  ©COPYRIGHT HUNTER INDUSTRIES, INC. 

CONFIDENTIAL AND PROPRIETARY

B1 FORMAT REVISION 08/27/12 

DENOTES FUNCTIONALLY CRITICAL POINTS

DENOTES CRITICAL INSPECTION POINTS

E0000

AAA

7/22/2012

REV

ECO

REVISION DESCRIPTION

DRFT

DATE

APVD

A

B

C

D

4

3

2

1

DIMENSIONAL

TOLERANCES:

REL.

DATE:

TITLE:

CHECKED

BY:

DESIGNER:

SCALE:

DRAWING NO.

REV.

PRINT

DATE:

UNLESS OTHERWISE SPECIFIED:

SURFACE FINISH:

ALL DIMENSIONS ARE IN INCHES

DO NOT SCALE DRAWING

1:2

BECKON, ASSEMBLY

DIS

21110495XXXX

N/A

ANGLES:

±1°

Hunter Industries

Engineering

1940 Diamond St.

San Marcos, CA 92078

C

D

A

B

4

3

2

1

SHEET  1  OF  1

.XX = ±.01

.XXX = ±.005

.XXXX = ±.0005

THIRD ANGLE PROJ.

C

SIZE:

5/11/2016

DRAWN

BY:

PRODUCT:

MATERIAL:

N/A

THIS DRAWING/DOCUMENT CONTAINS TRADE SECRET INFORMATION OF HUNT

ER INDUSTRIES, INC. USE, PUBLICATION, AND/OR 

DISCLOSURE OF THIS INFORMATION TO THIRD PARTIES ARE ALL PROHIBI

TED EXCEPT AS EXPRESSLY AUTHORIZED IN ADVANCE BY HUNTER. 

NO PATENT LICENSE IS GRANTED TO ANY INVENTIONS DESCRIBED AND/OR

 ILLUSTRATED HEREIN.  ©COPYRIGHT HUNTER INDUSTRIES, INC. 

CONFIDENTIAL AND PROPRIETARY

B1 FORMAT REVISION 08/27/12 

DENOTES FUNCTIONALLY CRITICAL POINTS

DENOTES CRITICAL INSPECTION POINTS

Rotate cartridge arm back into the neutral position. 
Twist the optic counterclockwise and pull outward to 
remove the optic.

Lift cartridge arm and turn counterclockwise to  
release lock. Pull complete cartridge out of  
luminaire housing.

Unfasten one screw only inside the cartridge using  
a #2 Phillips screwdriver.

E0000

AAA

7/22/2012

REV ECO

REVISION DESCRIPTION

DRFT

DATE

APVD

A

B

C

D

4

3

2

1

DIMENSIONAL

TOLERANCES:

REL.

DATE:

TITLE:

CHECKED

BY:
DESIGNER:

SCALE:

DRAWING NO.

REV.

PRINT

DATE:

UNLESS OTHERWISE SPECIFIED:

SURFACE FINISH:

ALL DIMENSIONS ARE IN INCHES

DO NOT SCALE DRAWING

1:1

CREST, ASSEMBLY

JG

21110494XXXX

N/A

ANGLES:

±1°

Hunter Industries

Engineering

1940 Diamond St.

San Marcos, CA 92078

C

D

A

B

4

3

2

1

SHEET  1  OF  1

.XX = ±.01

.XXX = ±.005

.XXXX = ±.0005

THIRD ANGLE PROJ.

C

SIZE:

5/11/2016

DRAWN

BY:

PRODUCT:

MATERIAL:

N/A

THIS DRAWING/DOCUMENT CONTAINS TRADE SECRET INFORMATION OF HUNTER INDUSTRIES, INC. USE, PUBLICATION, AND/OR 

DISCLOSURE OF THIS INFORMATION TO THIRD PARTIES ARE ALL PROHIBITED EXCEPT AS EXPRESSLY AUTHORIZED IN ADVANCE BY HUNTER. 

NO PATENT LICENSE IS GRANTED TO ANY INVENTIONS DESCRIBED AND/OR ILLUSTRATED HEREIN.  ©COPYRIGHT HUNTER INDUSTRIES, INC. 

CONFIDENTIAL AND PROPRIETARY

B1 FORMAT REVISION 08/27/12 

DENOTES FUNCTIONALLY CRITICAL POINTS

DENOTES CRITICAL INSPECTION POINTS

E0000

AAA

7/22/2012

REV ECO

REVISION DESCRIPTION

DRFT

DATE

APVD

A

B

C

D

4

3

2

1

DIMENSIONAL

TOLERANCES:

REL.

DATE:

TITLE:

CHECKED

BY:
DESIGNER:

SCALE:

DRAWING NO.

REV.

PRINT

DATE:

UNLESS OTHERWISE SPECIFIED:

SURFACE FINISH:

ALL DIMENSIONS ARE IN INCHES

DO NOT SCALE DRAWING

1:1

CREST, ASSEMBLY

JG

21110494XXXX

N/A

ANGLES:

±1°

Hunter Industries

Engineering

1940 Diamond St.

San Marcos, CA 92078

C

D

A

B

4

3

2

1

SHEET  1  OF  1

.XX = ±.01

.XXX = ±.005

.XXXX = ±.0005

THIRD ANGLE PROJ.

C

SIZE:

5/11/2016

DRAWN

BY:

PRODUCT:

MATERIAL:

N/A

THIS DRAWING/DOCUMENT CONTAINS TRADE SECRET INFORMATION OF HUNTER INDUSTRIES, INC. USE, PUBLICATION, AND/OR 

DISCLOSURE OF THIS INFORMATION TO THIRD PARTIES ARE ALL PROHIBITED EXCEPT AS EXPRESSLY AUTHORIZED IN ADVANCE BY HUNTER. 

NO PATENT LICENSE IS GRANTED TO ANY INVENTIONS DESCRIBED AND/OR ILLUSTRATED HEREIN.  ©COPYRIGHT HUNTER INDUSTRIES, INC. 

CONFIDENTIAL AND PROPRIETARY

B1 FORMAT REVISION 08/27/12 

DENOTES FUNCTIONALLY CRITICAL POINTS

DENOTES CRITICAL INSPECTION POINTS

1.

2.

3.

4.

Note:

 Do not remove adhesive 

thermal pads. Premature 
failure may result.

Faceplate and Lens

Содержание nBeckon-26

Страница 1: ...unsafe condition and void product warranty Do not block light emanating from product in whole or part Never operate the luminaire with missing or damaged lens Clean lens on a regular basis Entire lumi...

Страница 2: ...urple HV Grey 0 10V LUMINAIRE BUILDING Standard Voltage SV Universal Voltage UV High Voltage HV Input Power 120V 60Hz 110V to 277V 60Hz 220V to 240V 50Hz Dimming Phase 0 10V 0 10V Number of Wires 3 5...

Страница 3: ...duit connect to sleeve with couplings of choice 14 NPT For cabling install with cord glands and torque to 50 in lbs 5 6 Nm 5 Remove the wiring compartment cover and pull the wiring into the sleeve Lea...

Страница 4: ...uring remove wood frame and installation cover 13 Run incoming wiring from luminaire housing through the wiring compartment cover Connect wiring using the wiring diagram and approved wire connectors 1...

Страница 5: ...Service 1 844 200 4656 3 Product Installation continued 17 Using a 2 Phillips screwdriver turn the top adjustment screw to adjust the direction or angle of the LED cartridge One full turn 1 Use a torq...

Страница 6: ...C K O N A S S E M B L Y D IS 2 1 1 1 0 4 9 5 X X X X N A A N G L E S 1 H u n te r In d u st rie s E n g in e e rin g 1 9 4 0 D ia m o n d St Sa n M a rc o s C A 9 2 0 7 8 C D A B 4 3 2 1 S H E E T 1...

Страница 7: ...HIS INFORMATION TO THIRD PARTIES ARE ALL PROHIBITED EXCEPT AS EXPRESSLY AUTHORIZED IN ADVANCE BY HUNTER NO PATENT LICENSE IS GRANTED TO ANY INVENTIONS DESCRIBED AND OR ILLUSTRATED HEREIN COPYRIGHT HUN...

Страница 8: ...ate of invoice If a defect in a Holm product is discovered during the applicable warranty period Hunter will repair or replace at its option the product or the defective part This limited warranty doe...

Отзывы: