Holland Green Science 11111008 Скачать руководство пользователя страница 8

 

 

User Manual 

 

Version 1.0 
 

regulations. 

 
     

! ATTENTION (may affect operational performance or service life) 

 

The instrument is deenergised only when the power cable is  disconnected from the power 
source. 

 

Ensure the instrument and its accessories are protected external vibration. 

 

The Company reserves the right to modify the design and technical data of the pump without 
notice.  

 

Only accredited and qualified professional repair technicians can open the instrument or 
conduct required repairs. Persons performing repairs on the instrument other than those 
selected or approved by the Company shall operate to void any warranty contained 
hereinabove for the product 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 11111008

Страница 1: ...User Manual 1 Version 1 0 11111008 Anemos Scroll Vacuum Pump User Manual...

Страница 2: ...l Vacuum Pump 10 3 1 Introduction 10 3 2 Precautions 11 IV Technical Specifications 12 4 1 Specifications 12 4 2 Dimensions 13 V Installation and Operation 14 5 1 Operation environment requirement 14...

Страница 3: ...he applicable manufacturer s Published User Statement Limited User Statement or Limited License if any While this manual contains certain representations of the potential dangers from the instrument o...

Страница 4: ...to the extent such assignment is allowed by such original manufacturer or third party supplier In no event shall the Company have any obligation to make repairs replacements or corrections required in...

Страница 5: ...NG WITHOUT LIMITATION THOSE OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A SPECIFIC PURPOSE OR USE WHETHER ARISING FROM STATUTE OR OTHERWISE IN LAW OR FROM A COURSE OF DEALING OR USAGE OF TRADE...

Страница 6: ...VING RISE TO SUCH LIABILITY OR B ONE HUNDRED THOUSAND DOLLARS 100 000 WHICHEVER IS LESS With respect to any software products incorporated in or forming a part of the Product hereunder Buyer intends a...

Страница 7: ...clean antiskid and fireproof surface Ensure there is sufficient ventilation gaps and spacing above and around the instrument Ensure the instrument is stable and level and will not move due to vibrati...

Страница 8: ...cessories are protected external vibration The Company reserves the right to modify the design and technical data of the pump without notice Only accredited and qualified professional repair technicia...

Страница 9: ...ent or equipment or service without charge at its sole discretion Buyer assumes sole responsibility for any reliance on or use of such assistance and information and the company makes no warranty ther...

Страница 10: ...The vacuum pump offers a steady pumping speed over a wide pressure range Because the change of the compression volume is continuous the driving torque and power are almost constant The working cavity...

Страница 11: ...ned regularly and replaced every six months The silencer may cause the exhaust pressure of the pump to rise due to the air resistance and shorten the lifespan of the pump The vacuum pump is not suitab...

Страница 12: ...S 3 L min 180 Ultimate Vacuum mbar 0 008 Pa 0 8 Leak rate mbar l s 1 10 6 pa m 3 s 1 10 7 Motor voltage V Single phase 100 240 Motor power W 400 Motor speed rpm 1740 Dimension mm 430 L x 255 W x 290...

Страница 13: ...User Manual 13 Version 1 0 4 2 Dimensions...

Страница 14: ...from 5 C to 40 C If operated outside this temperature range the pump may be damaged The pump should not be used in a dusty environment or near corrosive gases Operating in such environments will reduc...

Страница 15: ...secured If the pump is used for the first time or used after a long period of inactivity open the inlet and outlet ports and run the pump for 5 minutes to remove any water vapor that might get into t...

Страница 16: ...ion interface No Signal Function Remark 1 5V 5V power 2 5V 3 GND 5V power ground 4 GND 5 485 Serial communication 485 7 FIC Pressure signal 1 5V 0 10V 13 485 Serial communication 485 15 15V Pressure s...

Страница 17: ...ied damage please contact serviceusa hollandgreenscience com The package includes the following items Item Description Quantity Main Unit 1 Quick Setup Card 1 Plastic cover 2 Power cable 1 NW25 Net fi...

Страница 18: ...ffect the performance and lifespan of the pump Inspection part Maintenance frequency Remark One year or 8000 hours Two years or 16000 hours Bearing o o O ring o o Tip seal o o Replace According to the...

Страница 19: ...g Damage of the O ring Replace the O ring Water vapor inside the pump Install a filter to prevent water vapor Open the inlet port to ATM for several minutes Run pump with gas ballast for about 24 hour...

Отзывы: