19
M3B116EN/ M3W116EN
M3B132EN/ M3W132EN
M3B316EN/ M3W316EN
M3B332EN/ M3W332EN
1
2
3
4
16A
32A
16A
32A
L1/N/PE
L1/N/PE
L1/L2/L3/N/PE
L1/L2/L3/N/PE
Copper, 3 X 4mm
2
,
Copper, 3 X 6mm
2
,
Copper, 5 X 4mm
2
,
Copper, 5 X 6mm
2
,
Sr No.
Rated current
Input terminals
Suggestion cable size
Product
As shown in Fig. 5-5, open the terminal cover, pass the prepared power cable through
the input cable interface, connect each cable to the input terminals according to the
terminal label.
Reset the terminal cover after wiring the input power cable.
Note: if you need the Ethernet to connect the CMS, you can pass a network cable with RJ-45 header
through the input cable interface and plug it into the network interface.
As shown in Fig. 5-6, hang the wallbox on the wall hanging accessories, and
then fix the locking screws on the left and right sides to complete the
installation.
• Step 4: Fixed the wallbox
Fig. 5-5 Wiring the input power cable
Fig. 5-6 Fixed the wallbox on the wall