HoldPeak HP-846A Скачать руководство пользователя страница 2

 

appears 

3) 

Wind flow unit (cube foot/minute) 

4) 

 

Wind flow unit (cube meter/minute) 

5)   

 

If measured value is over 9999, the symbol “X10 “ or   

“X100” will appear. 
6)     

         

Big  fans  :  indicate  wind  velocity  /flow  status, 

which was subject to Wind Velocity and revolving. 
  7)     

 

Wind velocity and flow display area. 

8)   

   

When  measuring  average  values  (one  of  the 

wind flow measuring Method) this symbol appears.   
9)   

 

  Showing minimum values. 

  10) 

 

MAX2/3 of maximum value measurement (one 

of the wind flow measuring method)   
  11) 

 

This  symbol  will  appear.  While  Read  stored 

record data. 
12)   

 

  Data holding 

  13) 

 

Data record by using the signal 

14) 

         

This symbol and serial number of stored record 

data will appear. While Read stored record data. 
  15)             

Low  battery  indicating  symbol,  please  replace 

battery if this symbol empty.   
16)   

   

Wind velocity unit (mile/hour)   

17) 

   

Wind velocity unit (sea mile/hour)   

18) 

 

Wind velocity unit (foot /minute)   

19)   

 

Wind velocity unit (kilometer/hour) 

20) 

 

Wind velocity unit (mete r/second) 

21)   

   

Beaufort scale 

22)     

     

M

2

 is used to indicate duct area in

 square meter 

when

 in flow function

 

         

"T

2

" Is used to indicate duct area in 

square 

feet 

when in flow function 
23)   

         

Wind temperature Celsius unit 

         

         

Wind temperature Fahrenheit unit 

24) 

 

Temperature value display or Duct area display area 

25) 

 

Wind temperature signal. 

26)       

 

small  fan  signal:    indicate  the  Wind  Temperature 

status 
27) 

Bar graph display of Beaufort scale   

 
SPECIFICATIONS 
Wind Velocity Range: 

Unit 

Wind 

Velocity 

Resolution 

Lowest 

Point of 

start value 

Accuracy 

m/s 

0.0-45.0 

0.001 

0.3 

±3%±0.1 

Ft/min 

0.0-8800 

0.01/0.1/1 

60 

±3%±20 

Knots 

0.0-88.0 

0.001/0.01 

0.6 

±3%±0.2 

Km/h 

0.0-140.0 

0.001 

1.0 

±3%±0.4 

Mph 

0.0-100 

0.001/0.01 

0.7 

±3%±0.2 

2.    Wind flow range: 

CMM: 0-999900m

3

/min 

CFM: 0-999900 ft

3

/min 

 

Unit 

Range 

Resolution 

Area 

CMM(M

3

/MIN) 

0-999900 

0.001-100 

0.001-9999 

CFM(FT

3

/MIN) 

0-999900 

0.001-100 

0.001-9999 

2.

 

Unit Conversation: 

 

 

m/s 

Ft/min 

Knots 

Km/h 

Mph 

m/s 

196.87 

1.944 

3.60 

2.24 

Ft/min 

0.00508 

0.00987 

0.01829 

0.01138 

Knots 

0.5144 

101.27 

1.8519 

1.1523 

Km/h 

0.2778 

54.69 

0.54 

0.6222 

Mph 

0.4464 

87.89 

0.8679 

1.6071 

4.    Air Temperature Range:

 

 

Unit 

Scale 

Resolution 

Accuracy 

 

0.0-45.0 

0.1 

±

1.0

 

 

32.0-113.0 

0.1 

±

1.8

 

5 . Operation Conditions: 

 

Temperature 

Humidity 

Host 

0-50

(32-122

80%RH 

Fan 

0-60

(32-140

6. Storage Conditions: 

Temperature 

-10-60

(14-140

Humidity 

80%RH 

7. Power supply : 6F22 9V

×

8. Low battery indicating : 6.8V

±

0.2V 

9. Stand by current 

2μA 

10. Operating Current Approx.18mA   
11. Battery use life :20H (Continuous Use ) 
12. Dimensions: 

Meter:165

×

85

×

35

 

Vane: 251

×

72

×

30

 

13. Net Weight :320g (Not Included Battery ) 
 

2. Operation 

Measurement of Wind Velocity and Temperature 

 

Recover the battery door , and install the batteries properly 
as shown in figure 1. 

  figure1:

 

Press the “

” key, all the symbols will be shown on the screen 

for 1 second, then the unit goes into current wind velocity and 
temperature  measuring  mode,  the  LCD  screen  shows  as 
following figure2:   

   
 
 

  figure2: 

 

Select your desired wind velocity and temperature unit 

(1)

 

Press  the  “UNIT”  key,  the  wind  velocity  unit  will  be 

auto change from (m/s、km/h、ft/min、knots、mph). 

(2)

 

Press the “℃/℉” , The temperature will be change 

between 

/

  mode. 

 

Hold the Anemometer with your hand, place the vane in the 

air flow with the air direction matching the direction of the 
arrows printed on the inner walls of the vane (Pleas do not 
extruded the fan leaf. Otherwise will cause the inaccuracy 
measurement)

 

   

Figure3   

(1)

 

Wait for two Sec, to make the data stability 

(2)

 

Place the vane in the same  direction of the wind to 

capture the accurate data . 

(3)

 

Press  “LIGHT”  Key  to  start  the  Backlight  Function, 

then press "LIGHT" BUTTON the LED will cut off , the light 
function will turn off. 

 

Wind /Air Temperature Measurement 

(1)

 

Wind  temperature  will  test  out  when  testing  Wind 

Velocity,  Small  Vanes  pattern  will  showing  along  with  the 
display of "TEMP" Symbol. 

Содержание HP-846A

Страница 1: ...easurement of 2 3V max and average wind flow Data holding storing and deleting function Low battery indicating function Auto power off function Button without any operation and the fan static after 5 minutes will be turned off Memory of 300 records Backlight function Pressing key audio alert Large LCD display Wind Handle Can Elongate DIAGRAM OF THE UNIT 1 LCD display 2 Max Min value switch 3 Power...

Страница 2: ... 0 999900 0 001 100 0 001 9999 2 Unit Conversation m s Ft min Knots Km h Mph m s 1 196 87 1 944 3 60 2 24 Ft min 0 00508 1 0 00987 0 01829 0 01138 Knots 0 5144 101 27 1 1 8519 1 1523 Km h 0 2778 54 69 0 54 1 0 6222 Mph 0 4464 87 89 0 8679 1 6071 1 4 Air Temperature Range Unit Scale Resolution Accuracy 0 0 45 0 0 1 1 0 32 0 113 0 0 1 1 8 5 Operation Conditions Temperature Humidity Host 0 50 32 122 ...

Страница 3: ...his time the LCD screen shows as above diagram Press the AREA key Letter on the LCD will disappeared at this time you can input duct area such as 1 2 press ENTER key confirm press again the OPTION key to select 2 3 V max the LCD screen as shown in figure 8 Figure 8 Aim the vane of the attached unit at duct area properly take measurement of 2 3 V max wind flow right away press again the OPTION key ...

Страница 4: ...is block or not connected 3 If the unit can not read the wind temperature value properly please check if the heat resistor is fall off or damaged by manual 4 If the unit can not read data properly please check it is operated under the rule temperature and humidity situation 5 when Measure the wind velocity the temperature display line don t show the number for temperature overflow or probe fault W...

Отзывы: