background image

2.Locating  a  hot  spot  aim  the  thermometer  outside  the
area  of  interest,  then  scan  across  with  up  and  down 
motions until you locate the hot spot.(please turn on the 
laser to for accurate measuring) 

3.Diagram description
(1)

 

MEAS button

Press the measurement button to display 

the surface temperature. 

 

(2)

 

Back light / Laser pointer button 

press it for turn 

on  Back  light,  press  again  for  turn  off

When 

product  working,  press  it  for  turn  on  Laser  pointer, 
press again for turn off. 

(3)

 

K-type  thermocouple  button 

Press  for  turn  on 

K-type  thermocouple  measure  mode

only  for 

K-type

Note  :  As  a  result  of  operation  principle  different  .  the 
measure  result  maybe  have  a  few  error  of  NTC  and 
infrared, it is normal situation. 

(4)

 

Celsius/Fahrenheit switch button: press direct for 

0

F

 select

.

 

(5)

 

LCD 

(6)

 

Battery  door:  When  replace  battery  door,  please 
using  the  finger  indents  to  pull  open  the  battery 
door. 

3

Maintenance 

1) Lens  cleaning:  Blow  off  lose  particles  using  clean

compressed air. Gently brush remaining debris away 
with a moist cotton cloth. 

2) Case  cleaning:  Clean  the  case  with  a  damp

sponge/cloth and mild soap. 

3)

Please  take  out  the  battery  when  not  using  for  a  long
time.

 

Note: 
1) Do not use solvent to clean lens.
2) Do not submerge the unit in water.

4

specifications 

Temperature 

range 

-30

  to 275

(-22to527

0

F) 

Accuracy 

±

2

,

-30

  to 0

(-22 to 32

0

F)

 

±

1

,

0

  to 65

(32 to 149

0

F)

 

±

1.5% of rdg+1

,

65

(149

0

F)

 

Emissivity 

0.95 

Ambient 

operating 

range 

0

  to ~60

(32 to 140

0

F) 

Relative humidity 

10-95% RH noncondensing 

Storage temperature 

-20~60

(-4~140

0

F) without battery 

Ambient 

temp 

range  of  guarantee 
for accuracy

 

23

~28

 

Weight/dimensions 

81g;56.5

×

20.5

×

95.0mm 

Power 

1.5V AAA

×

Battery life(alkaline) 

Laser models:12hrs 

Display spot size 

6:1 

Note: 
Display 

AL

 means Ambient temp lower than 0

Display 

AH

 means Ambient temp higher than 60

Display  above  code  in  normal  Ambient  temp,  probable 
means this meter was broken. 

Attached list 

Applicable Emissivity for 

Different Material ( For reference only) 

Material

 

Emissivity

Material

 

Emissivity

Asphaltum

 

0.90 to 0.98

 

Textile

Black

 

0.98

 

Beton

 

0.94

 

Human Skin

 

0.98

 

Cement

 

0.96

 

Soap bubble

 

0.75 to 0.80

 

Sand

 

0.90

 

Charcoal

powder

 

0.96

 

Soil

 

0.92 to 0.96

 

Lacquer

 

0.80-0.95

 

Water

 

0.92 to 0.96

 

Lacquer 

reluster

 

0.97

 

Ice

 

0.96 to 0.98

 

Rubber

Black

 

0.94

 

Snow

 

0.83

 

Plastic

 

0.85-0.95

 

Glass

 

0.90 to 0.95

 

Timber

 

0.90

 

Ceramic

 

0.90 to 0.94

 

Paper

 

0.70-0.94

 

Marble

 

0.94

 

Chromic oxide

 

0.81

 

Gypsum

 

0.80 to 0.90

 

Copper Oxide

 

0.78

 

Compo

 

0.89 to 0.91

 

Iron Oxide

 

0.78 to 0.82

 

Brick

 

0.93 to 0.96

 

Stainless steel 
and Aluminum

 

0.2-0.3

 

All manuals and user guides at all-guides.com

Отзывы: