2.2.8 Diode and Audible continuity test 

Range 

Description 

Test condition 

Display read approx. 

forward 

voltage 

of 

diode 

Forward    DC  current 
approx. 0.4mA 
Reversed 

DC 

voltage 

approx. 2.7V 

Built-in buzzer  sounds if 
resistance  is    less  than 
approx. 40

Ω 

Open circuit voltage 

approx. 0.5V 

Overload protection: 250V DC/250Vrms AC 

3. MEASURING INSTRUCTION
3.1 DC/AV Voltage measurement 

1) Connect    the  black  test  lead  to  "COM"  socket  and  red  test
lead to the "T

V

Ω

Hz" socket. 

2) Set the selector switch to desired "V" position .According to need
to press the "SELECT "button for AC/DC conversion 
3) Read the result from the LCD panel.

3.2 AC Current measurement 

1) Set the selector switch to desired"40A 

"400A 

  "1000A "

position. 

Note: 

As the jaw core may remain some magnetic force after using for 
a while. If the display can not reach "0" When Press the "REL

”, 

please take following process 

to correct it:

 

A. Open the JAWS several times. 

ACA test not to need the step 

2) Open the clamp by pressing the jaw-opening handle and insert
the cable to be measured into the jaw. 
3) Close the clamp and get the reading from the LCD panel.
4) Push the D.HOLD button to lock display value, push it again to exit.
5) Push the LIGHT button to light the back light.

Note: 

Before this measurement, disconnect the test lead with the meter 
for safety. 

3.3Resistance measurement 

1) Connect    the  black  test  lead  to  "COM"  socket  and  red  test
lead to the " T

V

Ω

Hz " socket. 

2) Set  the  selector  switch  to 

desired  "ΩCAP

"  position,  the 

present function is resistance measurement, if it is other function, 
push the 

“SELECT” to select resistance measurement. 

3) Connect the probes across circuit to be tested.
4) Read the result from the LCD panel.

Caution: 

Ensure  that  the  circuit  to  be  tested  is  "dead".  Max.  input

over-load: 250V rms

10sec; 

Don't allow in electricity loop of the online measurement,

measurement shall be first will loop before without electricity 

3.5 Capacitance measurement 

1) Connect    the  black  test  lead  to  "COM"  socket  and  red  test
lead to the " T

V

Ω

Hz " socket. 

2) Set  the  selector  switch  to  desired  "

Ω

CAP

"  position. 

According to "the SELECT" button can switch to the functionality 
needed to yourself 
3) Connect the probes to the capacitance to be tested.
4) Read the result from the LCD panel.

Caution: 

a) Capacitors should be discharged before being tested.
b) This device adopts charging mode to measure capacitance, so
when testing large capacitance, it will take longer time before the 
final  indication,  and  the  larger  capacitor,  the  longer  the  time  (For 
4000uF range, it will take about 30 seconds). 
c) When testing small capacitance, to assure the measurement
accuracy, first press "REL", then go on measuring. 
  Max. input over-load: 250V rms

10sec 

3.6 Frequency/Duty measurement 

1) Connect    the  black  test  lead  to  "COM"  socket  and  red    test
lead to the " T

V

Ω

Hz " socket. 

2)

Set the selector switch to desired "Hz" position.

3) Connect the probes to the point of measurement and read the
frequency from the display. 
4) Push "Hz/DUTY", you can measure the duty. Press again, go
back to frequency measurement. 
Max.input over-load: 250V rms

10sec 

3.7 Diode test 

1) Connect    the  black  test  lead  to  "COM"  socket  and  red    test
lead to the "T

V

Ω

Hz" socket. 

2) Set the selector switch to "

ΩCAP

" position. Push 

"SELECT" to select diode test. 
3) Connect  the  black  and  red  test  probe  to  the  cathode  (-)  and
anode  (+)  ends  of  diode  to  be  tested  respectively,  read  the 
forward voltage drop (junction) value from the display. If reverse 
connected the probes to diode, display shows over-load. 
  Caution: Ensure that the circuit to be tested is "dead". 
Max .input over-load: 250V rms

10sec 

3.8 Audible continuity test 

1) Connect    the  black  test  lead  to  "COM"  socket  and  red  test
lead to the " T

V

Ω

Hz " socket. 

2) Set the selector swi

tch to "ΩCAP

" position. 

3) Push "SELECT" to select audible continuity test.
4) Connect  the  probes  across  circuit  to  be  tested,  the  beeper
sounds continuously if the resistance is less than approx. 4

0Ω. 

Caution: Ensure that the circuit to be tested is "dead". Max .input 
over-load: 250V rms

10sec 

3.9 Temperature measurement 

1) Connect    the  black  test  lead  of    the  sensor  to  "T-"    socket
and the red test lead to the " T

V

Ω

Hz " socket. 

2) Set the selector switch to "

/

" position.

3) Put  the  sensor  probe  into  the  temperature  field  under
measurement. 
4) Read the result from the LCD panel.
Max .input over-load: 250V rms

10sec 

A. 

The  temperature  function  must  insert  the  thermocouple  in 

temperature test hole while examining temperature.   
B. 

According  to  "the  SELECT"  button  in  the 

  and 

  to 

switch between 
C. 

This meter inclosure WRNM-010 type contact thermocouple 

limit temperature is 250 

 (300 

 shortly ) ; 

D. 

Please don't change the thermocouple at will , otherwise we 

can't guarantee to measure accuracy ; 
E. 

Please  don’t  importing  the  voltage  in  the  temperature 
function. 

4. CARE AND MAINTENANCE
4.1 CARING FOR YOUR MULTIMETER 

  Your  Digital  Multi  meter  is  an  example  of  superior  design  and 
craftsmanship.  The  following  suggestions  will  help  you  care  for 
the multi meter so you can enjoy it for years. 
1) Keep the multi meter dry. If it gets wet, wipe it dry immediately.
Liquids can contain minerals that can corrode electronic circuits. 
2) Use  and  store  the  multi  meter  only  in  normal  temperature
environments. Temperature extremes can shorten the life of electronic 
devices, damage batteries and distort or melt plastic parts. 

3) Please  use  this  product  carefully.  Any  dropping  or  damage

will  lead  to  the  circuit  boards  break  or  product  unable  working 
normally 

4) When  take  current  measurement,  keep  the  cable  at  the

center of the clamp will get more accurate test result. 

5) Keep  the  multimeter  away  from  dust  and  dirt,  which  can

cause premature wear of parts. 

6) Wipe the multimeter with a damp cloth occasionally to keep it

looking  new.  Do  not  use  harsh  chemicals,  cleaning  solvents,  or 
strong detergents to clean the multimeter. 

7) Use only fresh batteries of the required size and type. Always

remove  old  or  weak  batteries.  They  can  leak  chemicals  that 
destroy electronic circuits. 
8) Please take out the battery when not using for a long time.

4.2 9Volt battery replacement 

1) Ensure the instrument is not connected to any external circuit.
Set  the  selector  switch  to  "OFF"  position  and  remove  the  test 
leads from the terminals. 
2) Open the cover of the battery cabinet by a screwdriver.
3) Replace the old batteries with the same type batteries.
4) Close the battery cabinet cover and fasten the screw.