3.0 INSTALLATION INSTRUCTIONS
To install the machine proceed as follows:
A.
Before raising the machine, ensure that the
chuck is completely closed, that the chuck arm
is lowered and the toolholder carriage is in all
the way in Fig.12.
397
Fig.12
B.
Remove the screws that secure the machine to
the pallet.
Lift the machine only with the two lifting lugs with a
belt or rope of appropriate length and strength
(300 cm - 10’) (Fig.12).
DO NOT SWING THE MACHINE WHEN
LIFTED.
DO NOT CUT THE REMOTE UNIT CORD
WHEN LOWERING THE MACHINE TO
THE GROUND.
3.1 ELECTRIC INSTALLATION
ALL
ELECTRICAL
CONNECTIONS
SHALL BE PERFORMED BY A LICENCED
TECHNICIAN. ALL SERVICE MUST BE
PERFORMED BY AN AUTHORIZED
SERVICE TECHNICIAN.
Check on the plate of the machine that the elec-
trical specifications of the power source are the
same as the machine.
The machine uses 400VAC, 50 Hz, 3Ph, 9.5 Amp.
Electrical specifications are clearly marked on a
label at the end of the electric cord.
Before connecting the machine to the power
source, check that the power supply has an effi-
cient grounding system.
Connect the electric cord of the machine with a
homologated plug.
There should be less than 1
Ω
between the ground
pin and earth ground.
NOTE:
The outlet installation must be verified by a li-
censed electrician before connecting the tire
changer.
NOTE:
The yellow with green wire in the cord is the
grounding wire.
Never connect the grounding wire to a live termi-
nal.
Check that the power supply has an automatic
circuit breaker with a differential circuit set at 30
mA.
The electric motor operates in a wide voltage
range (plus 10% - minus 7%) and frequency range
(50 or 60 cycles) and has a class of insulation suita-
ble for hot and moist climates.
3.2 MOTOR ROTATION CHECK
Once the machine is hooked-up, turn the machine
on using the ON/OFF switch.
Ensure that the rotation direction of the pump is
the same as indicated by the arrow on the motor
cover.
If not, reverse any two phase cables on the plug
(i.e. reverse the brown and the blue cable).
ANY DAMAGE CAUSED BY THE NON
APPLICATION
OF
THE
ABOVE
INSTRUCTIONS SHALL NOT BE DEBITED
TO THE MANUFACTURER AND WILL
VOID THE WARRANTY.