Use of the wheel balancer
press
▪
+
to preset the required value;
press
▪
to change unit of measurement
pre
▪
ss
to set the dimensions for ALU M cor-
rection mode.
press
▪
HOME
HOME
STOP
STOP
to return to the measurement screen
press
▪
to perform a measurement spin.
Defi nition of dimensions:
= DIAMETER:
Set the nominal diameter stamped
on the rim.
= WIDTH: Set the nominal width which is normally
stamped on the rim
= DISTANCE : With the MEGASTICK in the rest
position, measure the wheel-machine distance (in
cm). Set the value subtracting 1.5 cm.
5.5 MEASUREMENT RESULT
After performing a balancing run, the unbalance values are
displayed as well as arrows useful for positioning the correction
weight at the application point.
If laser = OFF
: after positioning and locking the wheel, apply
the weight vertically at the top.
If laser = ON
: apply the clip-on weights at 12 o’clock. If using
adhesive weights, when the correction position is reached,
the laser turns on indicating the point where to apply the
adhesive counterweight.
The symbol
is shown on the screen.
If the acoustic signal is enabled (
ACOUSTIC SIGNAL
),
the acquisition of the correction position is con
fi
rmed by a
“beep” alarm.
If wheel locking is enabled (
LOCK WHEEL
) the wheel is
automatically locked in the correction position. If the unba-
lance is less than the chosen threshold value, “0K” appears
instead of the unbalance value
to indicate, on that particular
side, that the wheel is in tolerance; the residual unbalance
can be displayed by pressing the
button with an
accuracy of 0.5 g (0.1 oz.)
The following buttons are enabled:
Display of residual unbalance.
Selection of correction mode (ALU1, ALU2, ALU
3M, ALUM, STATIC, DYNAMIC). When the mode
is changed, the unbalance values are recalcula
ted automatically on the basis of the previous
run,
(
ALU AND STATIC MODE
).
Residual unbalance printout (option)
Eccentricity measurement graph (option). The
symbol above the key turns red if eccentricity is
too
high.
WEIGHT LESS management
Unbalance split control for presettable compo
nents
(
“SPLIT” CONTROL
). Button only enabled in
STATIC, ALU M OR ALU 3M correction.
AUTO SELECT
Selection of special functions
Balancing run.
INDICATION
If the machine remains on this screen without being
used for more than the time preset in the Setup
parameters (6), the screen automatically returns
to the screen-saver.
Содержание Megaspin 800P_2
Страница 8: ...A B C D E F G SE2 MOUNTING SE2 MOUNTING ...
Страница 28: ......