![Hoffmann Megaplan Megaspin Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/hoffmann/megaplan-megaspin/megaplan-megaspin_use-and-maintenance-manual_2144175083.webp)
83
Ver. 04-2015
Use and Maintenance Manual
ENGLISH
Err. 21
Err. 22
Date and time setting error
1. Repeat the date and time setting function
2. Check that you have set numbers compatible with the date and
time format
Err. 31/
Err. 32/
Err. 33/
Err. 34/
Err. 39/
Err. 42
Firmware upgrade management error
1.
Check that you have loaded a file with extension BI5
2.
Repeat the firmware upgrade function
Err.50
Error in eccentricity measurement
using the external laser
1. Check that you have correctly mounted the wheel or rim
2. Check that during measurement (wheel at full speed), the red light of
the external laser is aimed at the tyre or the rim
3. Open the spindle, close the spindle and repeat the eccentricity
measurement function
Err.51
Error in eccentricity measurement
using the internal laser
1. Check that you have correctly mounted the wheel or rim
2. Check that during measurement (wheel at full speed), the red light of
the internal laser is aimed at the tyre or the rim
3. Open the spindle, close the spindle and repeat the eccentricity
measurement function
Err.60
Error: the spindle is not closing
1. Use the self-diagnostics function to check proper functioning of the
spindle
Err.61
Error: the spindle is not opening
1. Check the pneumatic system air pressure
2. Check the spindle opening/closing control microswitch
3. Check that there are no mechanical obstructions hindering spindle
opening/closing
Err.70
Error. Lift down and does not ascend
1. Use the self-diagnostics function to check proper functioning of the lift
2. Check proper functioning of the microswitch that detects the lift in
rest position
3. Check the pneumatic system air pressure
Err.71
Error. Lift up and does not descend
1. Use the self-diagnostics function to check proper functioning of the lift
2. Check proper functioning of the microswitch that detects the lift in
rest position
3. Check that there are no mechanical obstructions hindering lift descent
Err.72
Error. Lift up during unbalance,
eccentricity and taper measurement
1. Lower the lift before starting any measuring cycle
Err.75
Error in the taper calibration function
1. Use the self-diagnostics function to check proper functioning of the
external laser
2.
Check that the external laser light spot is aligned with the spindle
3. Check that you have correctly fitted the calibration tool
4. Repeat the taper calibration function
Err.100
Error in sending parameters from the
PC to the acquisition board
1. Reset the wheel balancing machine
If the problem persists:
1. Check the connection cables between the PC and the acquisition board
2. Replace the acquisition board
3. Replace the PC
Err. 120
Stepper motor initialisation error
1. Check functioning of the stepper motor
2. Check functioning of the encoder on the stepper motor slide
3. Check that there are no mechanical obstructions hindering laser
movement
4. Check the stepper motor power supply
5. Contact Technical Service
Err. 121
Err. 123/124
Err. 125/126
Err. 127/128
Err. 129/130
Internal laser motor control error
1. Reset the wheel balancing machine
If the problem persists:
1. Check compatibility between the software and the firmware
2. Reinstall the software and the firmware
Err. 141
Err. 143/144
Err. 145/146
Err. 147/148
Err. 149/150
External laser motor control error
1. Reset the wheel balancing machine
If the problem persists:
1. Check compatibility between the software and the firmware
2. Reinstall the software and the firmware
Diagnostics