6.15 WHEEL ANALYSIS
Press the button
from the first set of buttons on the measurement screen.
Goes to the peak/peak and first harmonic
graph screen
Goes to the tread analysis screen
Prints the information screen
Return to main screen
This screen shows all the data read in the various unbalance measurement and wheel analysis phases.
For more information, refer to the paragraphs
RUNOUT
TREAD
TAPER
.
The button
is displayed with a red I when:
▪
The first harmonic of the wheel runout exceeds the limit set in the setup parameters.
▪
The first harmonic value of the rim runout exceeds the limit set in the setup parameters.
▪
The tread value is less than the limit set in the setup parameters.
▪
The wheel taper value is considered unacceptable (indicator on red level).