Confirm that communication protocol is selected as LX200 in the astronomical programs.
Please note that the setting method for each program is slightly different. Follow the manual
provided by the software distributer.
The time and location of the simulation program do not match with the ones of TCS.
1.
Check the settings of the simulation software: Some simulation software supports a function
to download the data such as time and location of PC to TCS.
2.
If it is difficult to set the date/time and observatory location by software, use the functions of
TCS itself and set it the same as software.
3.
TCS does not allow the user to enter the time before 2017. Therefore, date/time information
only after 2017 is available.
Poor guide performance
1.
Try to adjust the guide speed from the System menu. Lower the guide speed for long focal
length guiding, and increase the guide speed for short focal length guiding.
2.
Check the status of the LED at the bottom of the TCS. LEDs directly connected to the guide
signal are arranged as RA +, DEC +, DEC-, RA-.
3.
Confirm whether all LEDs respond to the signal or not.
4.
Make sure that the mount, telescope and guide scope are securely fastened. You can also
check by gently shaking the tip of the telescope by hand.
5.
Try to turn off the PEC function. In rare cases, the guide signal and PEC processing may
interfere.
Date and time settings are not maintained between power downs.
-
Open the battery cover of the side of the device to replace the battery. Replace with a new CR
2032 lithium button cell.
Normally, the battery should be maintained for more than 2 years after purchase. If the
problem suddenly occurs before the expected battery life ends, contact the manufacturer or
the seller.
-
If the current date and time are cleared each time the power is turned off, try moving the
battery tray back and forth several times. Moisture or other causes may cause poor contact.
-
If the problem persists does not improve, replace the CR2032 button cell. When replacing the
battery, please refer to the above for instructions.
When the automatic meridian flip function is undesired for photographing.
-
Select Disable from [Meridian]-[Meridian Flip] Menu.
-
When disabling the meridian reversal function, always be careful of moving the telescope. In
this case, it is programmed to reject the GOTO command which goes below the horizontal
line.
When it automatically stops with a melody sound while tracking.
-
The RA Auto Stop function is activated.
-
Check the time and location settings to accurately calculate the meridian information.
-
Check the RA Auto Stop function.
-
Please check the message at the bottom of the screen.
When TCS receives a command from Object / GOTO, the error message is displayed without
moving.
-
Check the time and location setting.
Содержание Crux170HD
Страница 1: ...HOBYM Observatory 1 Crux170HD User Manual Ver 1 41...
Страница 9: ...HOBYM Observatory 9 Dimensions of the Mount...
Страница 19: ...HOBYM Observatory 19 TitianTCS V2 Quick Manual...
Страница 20: ...HOBYM Observatory 20...
Страница 21: ...HOBYM Observatory 21...
Страница 22: ...HOBYM Observatory 22...
Страница 23: ...HOBYM Observatory 23...
Страница 24: ...HOBYM Observatory 24...
Страница 25: ...HOBYM Observatory 25...
Страница 26: ...HOBYM Observatory 26...
Страница 27: ...HOBYM Observatory 27...
Страница 28: ...HOBYM Observatory 28...
Страница 29: ...HOBYM Observatory 29...
Страница 30: ...HOBYM Observatory 30...
Страница 31: ...HOBYM Observatory 31...
Страница 32: ...HOBYM Observatory 32...
Страница 33: ...HOBYM Observatory 33...
Страница 40: ...HOBYM Observatory 40 Horse Head Nebula FDK150 SBIG STL11K Crux170HD Hwang Injoon 2018...
Страница 41: ...HOBYM Observatory 41 M42 FDK150 SBIG STL 11k Crux170HD Hwang Injoon 2018...
Страница 42: ...HOBYM Observatory 42 Equipment setting reference Crux170HD TEC140FL Crux170HD VSD100...