background image

RXW

 

Temperature/RH

 

Sensor

 

(RXW

THC

B

xxx)

 

Manual

 

1

800

LOGGERS

 

4

 

www.onsetcomp.com

 

 

Consider

 

using

 

a

 

3/16

 

inch

 

padlock

 

to

 

restrict

 

access

 

to

 

the

 

mote.

 

With

 

the

 

mote

 

door

 

closed,

 

hook

 

a

 

padlock

 

through

 

the

 

eyelet

 

on

 

the

 

right

 

side

 

of

 

the

 

door

 

and

 

lock

 

it.

 

 

Make

 

sure

 

the

 

mote

 

is

 

mounted

 

a

 

minimum

 

of

 

1.8

 

m

 

(6

 

ft)

 

from

 

the

 

ground

 

to

 

help

 

maximize

 

distance

 

and

 

signal

 

strength.

 

 

Place

 

the

 

mote

 

so

 

there

 

is

 

full

 

line

 

of

 

sight

 

with

 

the

 

next

 

mote.

 

If

 

there

 

is

 

an

 

obstruction

 

between

 

two

 

sensor

 

motes

 

or

 

between

 

the

 

sensor

 

mote

 

and

 

the

 

manager,

 

then

 

use

 

a

 

repeater

 

mounted

 

on

 

the

 

obstruction.

 

 

There

 

should

 

not

 

be

 

more

 

than

 

five

 

motes

 

in

 

any

 

direction

 

at

 

their

 

maximum

 

transmission

 

range

 

from

 

the

 

manager.

 

Data

 

logged

 

by

 

a

 

wireless

 

sensor

 

must

 

travel

 

or

 

“hop”

 

across

 

the

 

wireless

 

network

 

from

 

one

 

mote

 

to

 

the

 

next

 

until

 

it

 

ultimately

 

reaches

 

the

 

manager

 

connected

 

to

 

the

 

station.

 

To

 

make

 

sure

 

data

 

can

 

successfully

 

travel

 

across

 

the

 

network,

 

the

 

mote

 

should

 

not

 

be

 

more

 

than

 

five

 

hops

 

away

 

from

 

the

 

manager.

 

 

The

 

HOBOnet

 

Wireless

 

Sensor

 

Network

 

can

 

support

 

a

 

maximum

 

of

 

50

 

motes.

 

 

Use

 

a

 

#4

40

 

screw

 

to

 

attach

 

a

 

ground

 

wire

 

to

 

the

 

port

 

on

 

the

 

back

 

of

 

the

 

mote

 

if

 

you

 

are

 

deploying

 

the

 

mote

 

in

 

a

 

location

 

where

 

lightning

 

is

 

a

 

concern.

 

Sensor

 

Mounting

 

Guidelines

 

 

It

 

is

 

recommended

 

that

 

the

 

probe

 

be

 

protected

 

from

 

direct

 

exposure

 

to

 

the

 

weather.

 

This

 

will

 

prolong

 

the

 

sensor

 

accuracy.

 

 

Refer

 

to

 

the

 

station

 

manual

 

and

 

Tripod

 

Setup

 

Guide

 

at

 

www.onsetcomp.com/support/manuals

 

for

 

more

 

information

 

regarding

 

setting

 

up

 

stations.

 

Maintenance

 

The

 

temperature/RH

 

sensor

 

is

 

sensitive

 

to

 

dust,

 

salts

 

and

 

other

 

airborne

 

contamination.

 

Periodically

 

inspect

 

the

 

RH

 

sensor.

 

If

 

contamination

 

is

 

present

 

on

 

the

 

protective

 

cap,

 

gently

 

rinse

 

it

 

with

 

cool

 

fresh

 

water.

 

If

 

the

 

sensor

 

itself

 

is

 

contaminated,

 

you

 

can

 

rinse

 

it

 

with

 

distilled

 

water.

 

Do

 

not

 

use

 

hot

 

water,

 

organic

 

solvents,

 

or

 

detergents.

 

Dry

 

before

 

use.

 

Periodically

 

inspect

 

the

 

mote

 

and

 

do

 

the

 

following:

 

 

Verify

 

the

 

mote

 

is

 

free

 

of

 

visible

 

damage

 

or

 

cracks.

 

 

Make

 

sure

 

the

 

mote

 

is

 

clean.

 

Wipe

 

off

 

any

 

dust

 

or

 

grime

 

with

 

a

 

damp

 

cloth.

 

 

Wipe

 

off

 

any

 

water

 

before

 

opening

 

the

 

mote.

 

 

Make

 

sure

 

the

 

interior

 

seal

 

is

 

intact

 

and

 

the

 

latches

 

are

 

fully

 

locked

 

when

 

the

 

mote

 

door

 

is

 

closed.

 

Updating

 

Mote

 

Firmware

 

If

 

a

 

new

 

firmware

 

version

 

is

 

available

 

for

 

the

 

mote,

 

use

 

HOBOlink

 

to

 

download

 

the

 

file

 

to

 

your

 

computer.

 

1.

 

In

 

HOBOlink,

 

go

 

to

 

Devices,

 

then

 

RX

 

Devices,

 

and

 

click

 

your

 

station

 

name.

 

2.

 

On

 

the

 

station

 

page,

 

click

 

Overview

 

and

 

scroll

 

down

 

to

 

Device

 

Information.

 

3.

 

Click

 

the

 

Wireless

 

tab.

 

This

 

icon

 

 

appears

 

next

 

to

 

the

 

mote

 

if

 

there

 

is

 

a

 

new

 

version

 

of

 

firmware

 

available.

 

4.

 

Click

 

the

 

firmware

 

 

upgrade

 

link.

 

Click

 

Download

 

and

 

save

 

the

 

firmware

 

.bin

 

file

 

to

 

your

 

computer.

 

5.

 

Connect

 

the

 

mote

 

to

 

the

 

computer

 

with

 

a

 

USB

 

cable

 

(open

 

the

 

mote

 

door

 

and

 

use

 

the

 

USB

 

port

 

to

 

the

 

right

 

of

 

the

 

LCD).

 

The

 

blue

 

LED

 

is

 

illuminated

 

while

 

connected.

 

6.

 

The

 

mote

 

appears

 

as

 

a

 

new

 

storage

 

device

 

in

 

the

 

computer’s

 

file

 

storage

 

manager.

 

Copy

 

the

 

downloaded

 

firmware

 

file

 

to

 

the

 

new

 

storage

 

device

 

(the

 

mote).

 

The

 

blue

 

LED

 

will

 

blink

 

slowly

 

while

 

the

 

file

 

is

 

copying.

 

7.

 

After

 

the

 

file

 

is

 

copied

 

to

 

the

 

mote,

 

the

 

LED

 

will

 

stop

 

blinking

 

and

 

remain

 

a

 

steady

 

blue.

 

Eject

 

the

 

storage

 

device

 

from

 

the

 

computer

 

and

 

disconnect

 

the

 

cable

 

from

 

the

 

mote.

 

The

 

firmware

 

installation

 

process

 

will

 

begin

 

automatically

 

on

 

the

 

mote.

 

The

 

blue

 

LED

 

will

 

blink

 

rapidly

 

while

 

the

 

firmware

 

is

 

installed.

 

Once

 

the

 

firmware

 

installation

 

is

 

complete,

 

the

 

LCD

 

symbols

 

return

 

and

 

the

 

mote

 

will

 

automatically

 

rejoin

 

the

 

network.

 

Notes:

 

 

Mac®

 

users:

 

A

 

message

 

may

 

appear

 

indicating

 

the

 

disk

 

has

 

not

 

ejected

 

properly

 

when

 

disconnecting

 

the

 

mote

 

from

 

the

 

computer.

 

The

 

mote

 

is

 

operational

 

and

 

you

 

can

 

ignore

 

the

 

message.

 

 

If

 

the

 

blue

 

LED

 

turns

 

off

 

abruptly

 

while

 

copying

 

the

 

file

 

or

 

installing

 

the

 

firmware,

 

a

 

problem

 

has

 

occurred.

 

Contact

 

Onset

 

Technical

 

Support

 

for

 

help.

 

Battery

 

Information

 

The

 

mote

 

uses

 

two

 

1.5

 

V

 

lithium

 

batteries

 

(HWSB

LI).

 

Lithium

 

battery

 

life

 

is

 

an

 

estimated

 

at

 

1

 

year,

 

but

 

varies

 

based

 

on

 

the

 

ambient

 

temperature

 

where

 

the

 

mote

 

is

 

deployed,

 

the

 

logging

 

interval,

 

the

 

number

 

of

 

tripped

 

alarms,

 

and

 

other

 

factors.

 

Estimates

 

are

 

not

 

guaranteed

 

due

 

to

 

uncertainties

 

in

 

initial

 

battery

 

conditions

 

and

 

operating

 

environment.

 

To

 

install

 

lithium

 

batteries:

 

1.

 

Open

 

the

 

mote

 

door.

 

2.

 

Remove

 

any

 

old

 

batteries

 

and

 

install

 

the

 

new

 

ones

 

observing

 

polarity.

 

The

 

mote

 

contacts

 

the

 

network

 

once

 

the

 

new

 

batteries

 

are

 

installed.

 

The

 

green

 

LED

 

blinks

 

quickly

 

while

 

the

 

mote

 

searches

 

for

 

a

 

network

 

to

 

join

 

and

 

then

 

blinks

 

slowly

 

while

 

it

 

completes

 

the

 

network

 

registration.

 

Once

 

the

 

mote

 

has

 

finished

 

joining

 

the

 

network,

 

the

 

green

 

LED

 

turns

 

off

 

and

 

the

 

blue

 

LED

 

then

 

blinks

 

indefinitely

 

while

 

the

 

mote

 

is

 

part

 

of

 

the

 

network.

 

 

WARNING:

 

Do

 

not

 

cut

 

open,

 

incinerate,

 

heat

 

above

 

85°C

 

(185°F),

 

or

 

recharge

 

the

 

lithium

 

batteries.

 

The

 

batteries

 

may

 

explode

 

if

 

the

 

mote

 

is

 

exposed

 

to

 

extreme

 

heat

 

or

 

conditions

 

that

 

could

 

damage

 

or

 

destroy

 

the

 

battery

 

cases.

 

Do

 

not

 

mix

 

battery

 

types,

 

either

 

by

 

chemistry

 

or

 

age;

 

batteries

 

may

 

rupture

 

or

 

explode.

 

Do

 

not

 

dispose

 

of

 

the

 

logger

 

or

 

batteries

 

in

 

fire.

 

Do

 

not

 

expose

 

the

 

contents

 

of

 

the

 

batteries

 

to

 

water.

 

Dispose

 

of

 

the

 

batteries

 

according

 

to

 

local

 

regulations

 

for

 

lithium

 

batteries.

 

Отзывы: