3. Programmable Functions
In programming mode, the functions can be configured in the following
sequence.
3.1 Clock programming
The factory presets the time at
. The time setting is not cleared during a
reset however.
3.2 Choice of HEAT / COOL mode
A convenient inversion function makes it possible to switch from HEAT to
COOL. This permits connection to an external cooling device instead of a
heater to counteract an increase in temperature.
3.3 Temperature Programming
The temperature is regulated with a precision of 0.1 °C. The temperature can
be set within the range 10 °C – 60 °C.
3.4 Nocturnal temperature programming
It is possible to program two turn-on/turn-off times (allows day and night
difference) to simulate the drop in temperature at night.
3.5 Temperature alarm setting
A visual alarm is displayed when the temperature exceeds or drops below the
programmed desired value. An alarm window b/- 0.1 °C and 10 °C
can be set. The factory setting is the value 00 (no alarm).
Example:
Temperature 25 °C, alarm /- 3 °C means that an
alarm is triggered below 22 °C and above 28 °C.