background image

 

In “Twisted mapping” mode, remote unit 
should be removed from the end of cables. 
Otherwise test result will be inaccurate. 

 
 
 

A

 warning will be displayed for unplugging 

the remote unit. Select “

Yes

” to continue. 

Select    go to previous menu. 

 
 
If the cable is shorter than 1.2 meter, the LANsmart Pro can not identify the twisted 
status, it will show the warning message “

Cannot

 detect cable under 1.2m”.     

 

Short Location 
LANsmart Pro can show which end of cable are shorted by using TDR technology. 
Also user can see short details on Wiremap menu.   
 
 

1.

 

Pair 1 (1-2) are shorted at near side of 
cable (TX) 

2.

 

Pair 2 (3-6) are shorted at far side of cable 
(RX) 

   (Short details display) 

 

 
 

No pins are shorted 
 

(Short details displa 

 

Wiremap 

Twisted Mapping 

Short Location 

Quick Test 

Please  

take off remote 

Yes 

 

No short detected 

     
 
                                                                 

Too much short

 

More than 2 pins are shorted 

one point

 

 
 
 
 
 
 
 
 
 
 
 

 

7

Содержание LANsmart Pro

Страница 1: ... Indicates the remote number of the remote identification unit for wire map test Incorporate Short Location function locate short position it determines if short is in the near or far end of the cable Measures twisted pairs of Cat5 Cat5E and Cat6 length without remote Measures length of flat 2 pin 4 pin and 6 pin telephone line Measures coax line length Self calibrating ability for non standard ca...

Страница 2: ... range for cable length 0 300m 0 984 feet Split pairs detection minimum 1 2m 3 94 feet Analog Tone Generator 1 KHz Digital Tone Generator Single Tone and Double Tone Operating Temperature 0 C 50 C 32 F 122 F Storage Temperature 30 C 50 C 22 F 122 F Humidity 10 90 Weight Main unit 120g Remote unit 20g Dimensions Master 120 80 33mm Remote 44 42 28 5mm Power source DC 6V 4 AAA 2 ...

Страница 3: ...ne line or coax line and calibrating parameters for non standard cable length test user must do the following configuration Follow the steps to configure the LANsmart Pro 1 Turn on the LANsmart Pro 2 LANsmart Pro will self diagnose first 3 Press the button to choose desired Configuration indicated by arrow SELECT Cable Test Length Test Identification Configuration Main Menu 4 Press the button and ...

Страница 4: ... 5e Cat6 Ntwk Cal Tel Cal Coax Cal In order to increase measuring accuracy for cable length test the setup is used to adjust calibrating parameters for non standard cables It includes twisted cables flat phone lines and coax lines For example network cable calibration page explanation Ntwk Cal 10 M YES Ntwk the calibration object is network twisted pair Cal xx M It is the cable length supplied by ...

Страница 5: ...Pro will begin to diagnose on the attached cable Cable Test Length Test Identification Configuration ENTER Wiremap Twisted Mapping Short Location Quick Test Diagnose ENTER Main Menu Cable test menu Transmitting side main unit 1 2 3 4 5 6 7 8 G 1 2 3 4 5 6 7 8 G Open Short Cross Idn Pass Split Rev Receiving side remote unit G Ground shield layer Idn The number of remote identification unit n 1 2 3 ...

Страница 6: ...6 7 8 G 1 2 3 4 5 6 7 8 G Id3 Pass Pins are miswire 1 2 3 4 5 6 7 8 G 8 1 2 7 5 6 4 3 Id3 Fail LANsmart Pro can also identify and indicate the remote identification number attached to the far end of the subject cable The number of remote identification unit is 3 1 2 3 4 5 6 7 8 G 1 2 3 4 5 6 7 8 G Id3 Pass Twisted Mapping The cable s twisted status can be analyzed and shown as map by selecting the...

Страница 7: ...s it will show the warning message Cannot detect cable under 1 2m Short Location LANsmart Pro can show which end of cable are shorted by using TDR technology Also user can see short details on Wiremap menu 1 Pair 1 1 2 are shorted at near side of cable TX 2 Pair 2 3 6 are shorted at far side of cable RX Short details display No pins are shorted Short details displa Wiremap Twisted Mapping Short Lo...

Страница 8: ...then select Quick Test Wiremap Twisted Mapping Short Location Quick Test First record a cable s pin out as test standard User should connect the standard cable with the main unit and the remote unit Then select Record Cable Record Cable Test Cable When recording is completed the beeper Beeps Bi and the LCD display a message Cable Recorded Cable Recorded Then select Test Cable for mass cable testin...

Страница 9: ...ndard twisted cable flat telephone line and coax line user should calibrate parameter by using a criterion cable first It is operated by Configuration Calibration menu Select Length from LANsmart Pro Main Menu Main Menu Cable Test Length Test Identification Configuration User should take off remote or it will lead to inaccurate result Please take off remote Yes Ntwk 93 8 M Pairs Length First LCD d...

Страница 10: ...nd the tone signal The Selected pin will be highlighted Select to stop Tone mode and return to previous menu Note Under normal conditions Tone on all pins will be louder than Tone on single pin Select the Digital Tone options from Identification menu Select Single tone or Double Tone from Digital Tone Press ENTER to send Digital Tone Port Finder Port finder is a distinctive feature Professionals r...

Страница 11: ...s all function module to stop working You must immediately turn off the unit Thank you for choosing Hobbes Corporation another innovation that is designed to improve trouble shooting network performance and productivity We are dedicated to providing the best quality and value for all your electronics needs Whether it s for individual corporate or governmental use Hobbes has the solution for you En...

Отзывы: