background image

9

1 2 3 4 5 6 7 8 G

BNC center pin

BNC shielding

C. 10Base-2 cable test
C1. Plug the attached two BNC adaptor cables on 
both RJ45 jacks, then connect both ends of  tested 
cables on BNC adaptor cables.

C2. As to the remaining procedures you may refer to
258A, TIA-568A/568B cable test from step A2 to A5.

Note: The center pin of  BNC should be read on LED 1
and shielding pin of  BNC should be read on LED 2.
As the 10Base-2 cable has only two wires, we suggest
reading the result of  LED scan by using manual mode.

Содержание 256551P

Страница 1: ...LANtest PoE user manual Multi Network PoE Cable Tester ...

Страница 2: ...eatures 2 Test Equipment Overview 3 Operation 1 PoE Power over Ethernet test 5 2 Loopback test A 258A TIA 568A 568B 6 cable test B Modular cable test 8 C 10Base 2 cable test 9 3 Remote test 10 Test Result 11 Warning 12 Warranty 12 ...

Страница 3: ...rifies the cables continuity open short and cross connect It s affordable so you can benefit the most Features Check the existence of PoE in seconds Identifies the type of PSE whether the PoE voltage is detected on the pair 12 36 Endspan or on the 45 78 Midspan Compliant with IEEE802 3af and IEEE802 3at standard Wiring configuration for Cat5 Cat5e Cat6 Cat7 coaxial and modular telephone cables by ...

Страница 4: ...ote unit it can test installed cables behind walls via wall plates or patch panels Features auto or manual scan Test Equipment Overview LANtest PoE Remote Terminator 1 2 3 4 5 6 7 8 GND 1 2 3 4 5 6 7 9 10 11 12 8 3 ...

Страница 5: ... display for receiving end Jack 2 5 Power switch 6 LED scanning mode switch 7 Test switch for manual scan 8 RJ45 jack for PoE test 9 RJ45 jack 10 LED display for receiving end same as Jack 2 11 Ground LED for receiving end 12 Battery compartment On back of main unit 4 ...

Страница 6: ... the LEDs will indicate the standard PoE voltage if detected It will display the voltage detected on pair 12 36 or 45 78 If an unsolicited voltage above 24VDC detected on the network the PoE LEDs will immediately light on without delay The LEDs will not turn on if detect any voltage under 24VDC 5 or ...

Страница 7: ...ng receiving RJ45 jack A2 Slide power switch on the upper row LEDs will start to scan in sequence if the LED scanning mode switch is press on Auto mode or the LED will light on pin 1 if the scanning switch is release on Manual mode Note You have to make sure the battery power is sufficient If battery power is low the LEDs will be dimmed or off and the test result will be incorrect 6 ...

Страница 8: ...her row of LED will light up simultaneously A5 LED displays the result of the pin configuration for the cable being tested If you fail to read the result in the first run of LED scan you may read it again in the next run of LED scan or use the manual mode and press the test switch to scan each pin manually to display each result ...

Страница 9: ...B Modular cable test Please follow the procedure of 258A TIA 568A 568B cable test However the LED display should be read as below 8 1 2 3 4 5 6 1 2 3 4 5 6 7 8 G RJ11 RJ45 ...

Страница 10: ...th ends of tested cables on BNC adaptor cables C2 As to the remaining procedures you may refer to 258A TIA 568A 568B cable test from step A2 to A5 Note The center pin of BNC should be read on LED 1 and shielding pin of BNC should be read on LED 2 As the 10Base 2 cable has only two wires we suggest reading the result of LED scan by using manual mode ...

Страница 11: ...e cable being tested is already installed on the patch panel or wall plate you may use the adaptor cable to solve the connector gender problem B Now set the Auto Manual switch on Auto mode if you work alone C Read the test result from LED display on remote unit Note The LED display on remote unit was scanned in sequence corresponding to the sourcing end of main unit ...

Страница 12: ...3 4 5 6 7 8 G Pin 3 and pin 6 are miswired Test Result 1 Continuity 1 2 3 4 5 6 7 8 G Pin 2 and pin 3 are shorted 1 2 3 4 5 6 7 8 G Pin 2 is continued 1 2 3 4 5 6 7 8 G Pin 2 is opened 3 Short 2 Open 4 Miswire ...

Страница 13: ... The device is guaranteed for two years after completing the registration procedure from the date of original sale in Hobbes Group web site The manufacturer will repair the device free of charge if manufacturer determines the product failed due to manufacture defect This warranty is only valid if the device is used for its intended purposes only Consumables such as connector can not be repaired un...

Страница 14: ......

Отзывы: