7.
Trouble shooting
Fault
Cause
Correction
machine does not start
uncorrect position of feed head
make sure the feed head is locked
correctly
pusher plate not correctly
lower pusher plate into feed head
positioned
site fusing or circuit breaker
check fusing / circuit breaker
blown
(wall box)
machine stops during operation
pusher plate not correctly
lower pusher plate into into feed head
and cannot be re-started
positioned
site fusing or circuit breaker
check fusing / circuit breaker
blown
(wall box)
motor overload protection
let overload protection cool, the
has cut machine off
machine may be re-started after
(i.e. when cutting hard product
some minutes
for a long time without stopping)
low output or
wrong disc in use
see chapter 3 (cutting tool guide)
poor cutting results
disc damaged
check disc (sharpness)
too strong feed pressure
a slight feeding pressure leads to
of pusher
the best cutting results for most
products
As continued product improvement is a policy of HOBART, specifications are subject to change without notice.
Printed in Germany
AG-20264-B-02-93-TD