4. MAINTENANCE INSTRUCTIONS
IMPORTANT
Maintenance and reparation works should be made by the INDUSTRIAL SALVA, S.A. Official
Technical Service or by one of our distributors.
IMPORTANT: Before carrying out any repairing or servicing of the electrical oven parts, the
magnetothermical protection devices located behind the control panel must be switched off. As far
as possible, work with the current disconnected from the power supply..
Daily maintenance
The glass panes of the door are to be cleaned carefully and with soft, nonabrasive detergents, to avoid
damaging the silkscreen print. To access the inside of the panes, the mould on the opposite side of the
hinges must be slid upwards in order to let the pane down. Carry out the same procedure inversely to put
the pane back, making sure the rubber seal is well placed.
Monthly maintenance
The internal parts of the oven should be cleaned: floor, roof, and sliders (to clean the internal parts of
the oven it is necessary to withdraw the sliders from the chamber. (see point 2.3)..
The internal parts of the oven should be cleaned: floor, roof, and sliders (to clean the internal parts of
the oven it is necessary to withdraw the sliders from the chamber. (see point 2.3).
NOTE:
If this oven is been used continuously without stop, the internal parts of the oven has to be
cleaned
more than once a month.
6 month period maintenance
(
should be made by the Official Technical Service of INDUSTRIAL
SALVA, S.A.
)
The motor cavity and sorroding areas must be cleaned.
NOTE:
Lach of clean may causean early failure on the electrical motor.
The electrical parts of the oven should be cleaned. Special care should be taken in not wetting the
oven controls, since major faults could occur in the electrical system.
NOTE:
Dust and flour could cause malfunctions of the electrical components of the electrical