![Hobart CLF26D-10 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/hobart/clf26d-10/clf26d-10_instruction-manual_2142090009.webp)
INSTRUCTION MANUAL FOR DISHWASHERS
Page 8 of 15
GB
START
BOILER
TANK
•
Close the door and turn on the machine.
•
With the cycle selection button shown at the side,
select the resin regeneration cycle (the
corresponding indicator lamp turns green).
START
BOILER
TANK
•
To start the cycle that lasts about 20 minutes, press
the start / start cycle button shown at the side (the
corresponding indicator lamp blinks). The machine
turns off by itself when the cycle ends.
•
To change the number of cycles between one
regeneration and the next, refer to the chapter
“Adjustment and controls”.
4.9
End of service
•
At the end of the day always drain the machine as
described in the “Machine draining” section.
•
Disconnect the power supply by means of the
main switch and close the external water cock.
•
Perform routine maintenance and clean the
machine as described in the “Maintenance” section.
•
If possible, leave the door ajar to prevent the
formation of bad smells inside.
4.10
Self-test and indication of anomalies
The machine has a set of devices for the control and safety of operation. The anomaly or alarm
condition is indicated on the tank and boiler temperature displays. The user must check whether
or not malfunctioning has occurred and take consequent action. If the assistance of a
qualified technician is necessary, you must turn off the machine, disconnect it from the
electric line and shut off the tap. The user must NOT meddle with the machine.
CAUTION! Turning off and then turning on the machine “resets” the indication, which
afterwards will reappear if the problem has not been solved
Message displayed
Anomaly or alarm found
Line indicator lamp is blinking (*): the incoming water control is not
working. To reactive the control, you have to disconnect and reconnect
the machine to the electric line. If the indication appears again, contact
a qualified technician.
TANK /
BOILER /
Insufficient water delivery (*): the quantity of incoming water is not
sufficient for complete rinsing. When the problem has been solved, run
a complete washing cycle. If the indication appears again, contact a
qualified technician.
TANK /
BOILER /
Excessive water pressure or delivery (*): if the message appears
often, it is necessary to have the water supply checked by a qualified
technician.
TANK /
BOILER /
Lack of incoming water (*): rinsing not carried out. When the problem
has been solved, run a complete washing cycle. If the indication
appears again, contact a qualified technician.
TANK /
BOILER /
Discharge time out: The tank has not drained completely. Check the
overflow cap has been removed. Try performing another discharge
cycle. Should the problem persist, contact a qualified technician.
Содержание CLF26D-10