OM-925 Page 13
5-3. Process/Polarity Table
Process
Polarity
Cable Connections
Process
Polarity
Cable To Gun
Cable To Work
GMAW
−
Solid wire with shield-
ing gas
DCEP
−
Reverse polarity
Connect to positive (+) out-
put terminal
Connect to negative (
−
) output
terminal
FCAW
−
Self-shielding wire
−
no shielding gas
DCEN
−
Straight Polarity
Connect to negative (
−
)
output terminal
Connect to positive (+) output
terminal
CHANGING
POLARITY
5-4. Changing Polarity
1
Lead Connections For Direct
Current Electrode Negative
(DCEN)
2
Lead Connections For Direct
Current Electrode Positive
(DCEP)
Always read and follow wire
manufacturer’s recommended
polarity, and see Section 5-3.
Close door.
Ref. 209 228 / Ref. 209 229
1
2
DCEN
Electrode negative for
flux cored wire
DCEP
Electrode positive for
solid wire
Содержание H-10 Gun
Страница 24: ...OM 925 Page 20 6 2 Weld Parameter Chart For 115 VAC Model ...
Страница 25: ...OM 925 Page 21 217 618 A ...
Страница 26: ...OM 925 Page 22 6 3 Weld Parameter Chart For 230 VAC Model ...
Страница 27: ...OM 925 Page 23 217 754 B ...
Страница 33: ...OM 925 Page 29 SECTION 8 ELECTRICAL DIAGRAM 217 621 A Figure 8 1 Circuit Diagram For 115 VAC Model ...
Страница 34: ...OM 925 Page 30 217 755 A Figure 8 2 Circuit Diagram For 230 VAC Model ...
Страница 45: ...OM 925 Page 41 Notes ...