Version date: February 13
th
, 2017
Troubleshooting 43
7
User instructions
HOAF thermHIT® 75M/100M/125M
Chapter 7 - Troubleshooting
7.3 Checks for service technicians
If there are faults which can not be solved by carrying out the instructions as
stated in chapter 7 'Troubleshooting', then check the following:
The checking activities described in this section
may only be carried out by properly trained
service mechanics.
1.
Check that the burner is not polluted.
Method:
• Visually
inspect
and clean if necessary.
•
Ignite
the burner if possible.
•
Lift
the burner housing and check that all the burners regularly burn.
Make sure to keep sufficient distance when you
look under the HOAF thermHIT® 75M/100M/
125M .
Warning! The burners may only be ignited in the
open air.
2. Check
that the tip of the spark plug is in the middle of the flame during the
process. See section 8.1 'Spark plug' for details regarding the position and
distance.
3. Check
that the power cable of the spark plug is undamaged.
4. Check
that the connection between the spark plug and the power cable is
good.
5. Check
the electrical wiring for loose contacts or damage.
Содержание thermHIT 75M
Страница 2: ...Edition Date Version 1 February 13th 2017 1 0 Version date February 13th 2017 2 ...
Страница 4: ...P Version date February 13th 2017 4 Preface User instructions HOAF thermHIT 75M 100M 125M Preface ...
Страница 8: ...C User instructions HOAF thermHIT 75M 100M 125M Contents Version date February 13th 2017 8 Contents ...
Страница 46: ...Version date February 13th 2017 46 Settings 8 User instructions HOAF thermHIT 75M 100M 125M Chapter 8 Settings ...
Страница 66: ...HOAF Infrared Technology Münsterstraat 14 7575 ED Oldenzaal The Netherlands Place stamp here ...