Version date: February 13
th
, 2017
42 Troubleshooting
7
User instructions
HOAF thermHIT® 75M/100M/125M
Chapter 7 - Troubleshooting
5. The
HOAF
thermHIT® 75M/
100M/125M
is
ignited, but goes off
after a few seconds.
or..
6. The
HOAF
thermHIT® 75M/
100M/125M
is not
burning evenly.
or..
7. The
HOAF
thermHIT® 75M/
100M/125M
turns on
and off.
Note! After ignition, the tip of the spark plug
"feels" if the flame is present. A perfect
connection between the spark plug and the
automatic firing device is a prerequisite for the
operation of the device. The ionisation flow
should be able to reach the automatic firing
device uninterruptedly.
1.
Check that there is enough gas present in the
gas bottle.
2.
Check that the correct gas is used (no butane!).
3.
Check that the bottle is used.
(for
HOAF thermHIT® 75M/100M/125M
: liquid
intake).
4.
Check that the tip of the spark plug is in the
middle of the flame during burning.
Method:
• Light the burner, lift the burner and look at
least 2 meters behind the burner if the tip of
the spark plug is in the middle of the flame.
5.
Close the gas valve and check that there is no
dirt under the
HOAF thermHIT® 75M/100M/
125M
at the burners.
6.
Make sure the nozzles are "open".
Method:
• Ignite the burner, lift the burner and look at
least 2 meters behind the burner if all burners
smoothly burn.
7.
Check that the voltage is 12 VDC. If not, the
battery is empty and it must be recharged. If the
battery after charging still does not deliver the
required voltage, then the battery must be
replaced
8.
Check the electrical wiring for loose wires and/or
damage.
9.
Check the spark plug cable for damage.
10.
Check the connection of the spark plug cable
with the spark plug.
11.
Check the connection of the automatic firing
device with the spark plug cable.
12.
Replace the automatic firing device with a new
one.
13.
If no solution can be found, please contact the
dealer.
Problem
Action
Содержание thermHIT 75M
Страница 2: ...Edition Date Version 1 February 13th 2017 1 0 Version date February 13th 2017 2 ...
Страница 4: ...P Version date February 13th 2017 4 Preface User instructions HOAF thermHIT 75M 100M 125M Preface ...
Страница 8: ...C User instructions HOAF thermHIT 75M 100M 125M Contents Version date February 13th 2017 8 Contents ...
Страница 46: ...Version date February 13th 2017 46 Settings 8 User instructions HOAF thermHIT 75M 100M 125M Chapter 8 Settings ...
Страница 66: ...HOAF Infrared Technology Münsterstraat 14 7575 ED Oldenzaal The Netherlands Place stamp here ...