A note about logger channels:
The LoLog is available in several different configurations for Pressure, Flow and
other sensors. Data is presented to the viewer in Channels and Channel numbers
are allocated in the factory by priority of sensor type. So, where fitted, analogue
sensors, e.g. Pressure transducers, Depth measurement devices and 4-20mA flow
sensors, will always come through on CH1; and digital inputs, e.g. pulse counters,
will take any remaining channel numbers.
Radwin automatically detects the configuration of the logger and will prompt you
according
to
the
type
of
Transducer
appropriate
to
that
input.
The following example will set up 1 pressure transducer and 1 flow channel for a
logger configured in the factory for 1 pressure and 1 x bi-directional flow.
For more specific details on other variants or if you experience problems, please
contact HWM support
10. The Channel 01 configuration menu appears as below:-
Click <<Next>> to continue.
11. The Channel 02 configuration menu appears as below:-
Again, tick the “Enabled” box to switch the channel ON.
12. As you are configuring a Digital pulse input, you need to configure the number of
Units Per Pulse to match the output from the Pulse Unit on your meter. Check your
meter for these details Click <<Configure>> to select your transducer type.
To turn ON the Pressure
channel, tick the “Enabled” box.
The default transducer is for a
pressure
transducer
with
a
Calibration factor of 0.1. If you are
configuring any other type of
sensor, please refer to HWM
support.
Choose how the logger will
measure pulses from the
dropdowns, “Count” counts each
pulse received by the logger,
“Event” converts the time
between pulses for slow flow
rates.
If you do not wish to count every
pulse for high rates,
Choose every “nth pulse”.