background image

Technical Data

13 (16)

8

Technical Data

PC address range

Plug & Play

Interrupts

Plug & Play

Microcontroller

32 bit microcontroller

Dimension

Approx. 74 x 149 mm

Operating temperature

-20 °C to +70 °C

Galvanic isolation

1 kV for 1 second

8.1

CAN-IB210/XMC

CAN interface

2 CAN interfaces; CAN 2.0 A/B; D-Sub-9 plug according to CiA 303-1,
optional CAN low-speed, optional 4 CAN interfaces via MultiCAN
expansion

LIN interface

Optional up to 2 LIN (ISO 9141) interfaces; D-Sub-9 plug

PC bus interface

XMC

Power supply

3.3 V DC, 600 mA typ.

8.2

CAN-IB410/PMC

CAN interface

2 CAN interfaces; CAN 2.0 A/B; D-Sub-9 plug according to CiA 303-1,
optional CAN low-speed, optional 4 CAN interfaces via MultiCAN
expansion

LIN interface

Optional up to 2 LIN (ISO 9141) interfaces; D-Sub-9 plug

PC bus interface

PMC

Power supply

3.3 V DC, 650 mA typ.

8.3

CAN-IB610/XMC

CAN interface

2 CAN/CAN-FD interfaces; CAN 2.0 A/B; D-Sub-9 plug according to CiA
303-1, optional CAN low-speed

LIN interface

Optional up to 2 LIN (ISO 9141) interfaces; D-Sub-9 plug

PC bus interface

XMC

Power supply

3.3 V DC, 600 mA typ.

8.4

CAN-IB810/PMC

CAN interface

2 CAN/CAN-FD interfaces; CAN 2.0 A/B; D-Sub-9 plug according to CiA
303-1, optional CAN low-speed

LIN interface

Optional up to 2 LIN (ISO 9141) interfaces; D-Sub-9 plug

PC bus interface

PMC

Power supply

3.3 V DC, 600 mA typ.

PC CAN Interface User Manual

4.01.0310.20000 1.2 en-US

Содержание Ixxat CAN-IB PMC Series

Страница 1: ...PC CAN Interface CAN IB Series XMC and PMC USER MANUAL 4 01 0310 20000 1 2 en US ENGLISH...

Страница 2: ...range of possible applications of the product and because of the many variables and requirements associated with any particular implementation HMS Industrial Networks cannot assume responsibility or...

Страница 3: ...neral Safety Instructions 5 2 3 Intended Use 5 3 Scope of Delivery 5 4 Features 6 5 Installation 6 5 1 Installing the Software 6 5 2 Installing the Hardware 7 6 Connections 8 6 1 Overview 8 6 2 CAN Bu...

Страница 4: ...PC CAN Interface User Manual 4 01 0310 20000 1 2 en US 10 Disposal 14 A Regulatory Compliance 15 A 1 EMC Compliance CE 15 A 2 FCC Compliance Statement 15...

Страница 5: ...operate the product 1 2 Related Documents Document Author User Manual Expansions for CAN IB Series for PCI PCIexpress HMS Installation Guide VCI Driver HMS 1 3 Document History Version Date Descriptio...

Страница 6: ...is is an external link URL www hms networks com Safety advice is structured as follows Cause of the hazard Consequences of not taking remediate action How to avoid the hazard Safety signs and signalwo...

Страница 7: ...e Technical Data p 13 Protect product from fire Do not paint the product Do not modify or disassemble the product Service must be carried out by HMS Industrial Networks Store products in dry and dust...

Страница 8: ...PMC P1386 1 Draft 2 4 CAN IB210 XMC and CAN IB410 PMC up to 4 CAN channels high low speed optional switchable expandable via fieldbus expansion and MultiCAN expansion CAN IB610 XMC and CAN IB810 PMC...

Страница 9: ...r XMC 2 PCI connector PMC Make sure that power is off Plug the PCIe connector 1 resp the PCI connector 2 in the corresponding plot of the carrier card Make sure that the interface is securely held on...

Страница 10: ...ound through a 1 M resistor and a 10 nF capacitor The shields of the CAN connectors are connected directly together For a not galvanically isolated interface the CAN ground and PC ground are at the sa...

Страница 11: ...used to extend each CAN circuit with fieldbus expansions for additional fieldbuses exclusively galvanically isolated interfaces The signals of the additional fieldbuses are applied to the correspondi...

Страница 12: ...ls of the fieldbus expansions are connected to the appropriate D Sub 9 connector Simultaneous operation of low speed CAN and LIN is also possible Use fieldbus expansions exclusively in conjunction wit...

Страница 13: ...e with CAN IB210 XMC and CAN IB410 PMC CAN IB610 XMC and CAN IB810 PMC do not support a MultiCAN expansion The use of fieldbus expansions is not possible if a MultiCAN expansion is used Fig 5 MultiCAN...

Страница 14: ...s Install the expansion see Installation p 10 Observe different pin allocation of D Sub 9 connector Pin Allocation Using MultiCAN PB Pin No Signal CAN 1 3 Signal CAN 2 4 1 CAN3 low high speed CAN4 low...

Страница 15: ...Sub 9 plug according to CiA 303 1 optional CAN low speed optional 4 CAN interfaces via MultiCAN expansion LIN interface Optional up to 2 LIN ISO 9141 interfaces D Sub 9 plug PC bus interface PMC Power...

Страница 16: ...ne contacts on www ixxat com 9 2 Return Hardware Fill in the form for warranty claims and repair on www ixxat com support product returns Print out the Product Return Number PRN resp RMA Pack product...

Страница 17: ...ed and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a re...

Страница 18: ...last page 2019 HMS Industrial Networks Box 4126 300 04 Halmstad Sweden info hms se 4 01 0310 20000 1 2 en US 2019 06 18 13689...

Отзывы: