Figure 5.14 

Intesis MAPS Receive/Send tab 

 
 

After any configuration change, do not forget to send the configuration file to the Intesis using the Send 
button in the Receive / Send section. 

 
 

5.2.6  Diagnostic 

To help integrators in the commissioning tasks and troubleshooting, the Configuration Tool offers some specific tools 
and viewers. 
 
In order to start using the diagnostic tools, connection with the Gateway is required. 
 
The Diagnostic section is composed by two main parts: Tools and Viewers. 
 

 

Tools 

Use  the  tools  section  to  check  the  current  hardware  status  of  the  box,  log  communications  into 
compressed files to be sent to the 

support, change the Diagnostic panels’ view or send commands to 

the gateway. 
 
 

 

Viewers 

In order to check the current status, viewer for the Internal and External protocols are available. It is 
also available a generic Console viewer for general information about communications and the gateway 
status and finally a Signals Viewer to simulate the BMS behavior or to check the current values in the 
system. 

 

 

Figure 5.15 

Diagnostic

 

 

 
More information about the Diagnostic section can be found in the Configuraion Tool manual. 
 
 

 

Содержание IBASCBAC3K00000

Страница 1: ...BACnet MSTP and BACnet IP client USER MANUAL Issue date 10 2018 r1 1 ENGLISH...

Страница 2: ...es and are only intended to help improve understanding of the functionality and handling of the product In view of the wide range of possible applications of the product and because of the many variab...

Страница 3: ...information is subject to change without notice URL https www intesis com 3 28 Gateway for the integration of BACnet MSTP and BACnet IP installations into ASCII IP or ASCII Serial enabled monitoring a...

Страница 4: ...Address Map 10 3 5 Points definition 10 3 6 ASCII messages 12 4 Connections 13 4 1 Powering the device 14 4 2 Connection to ASCII 14 4 2 1 ASCII TCP IP 14 4 2 2 ASCII Serial 14 4 3 Connection to BACn...

Страница 5: ...e simple text messages through EIA232 or EIA485 serial port or Ethernet TCP IP port for example Extron LiteTouch systems The gateway acts as a BACnet IP Client device in its BACnet interface reading w...

Страница 6: ...f view each register corresponding to a present_value of an object on a particular BACnet server device When a new value is read from BACnet for a given object present_value the new value is updated i...

Страница 7: ...ignal Analog Value Present Value Analog signal i e Temperature set point value Binary Input Present Value Digital signal i e ON OFF status Binary Output Present Value Digital signal i e ON OFF command...

Страница 8: ...in alternatively implement a BBMD itself Bacnet IP Broadcast Management Device This functionality facilitates communication of devices in other networks with the devices in the network where Intesis i...

Страница 9: ...the following BACnet object types supported by Intesis AI Analog Input AO Analog Output AV Analog Value DI Digital Input DO Digital Output DV Digital Value MI Multistate Input MO Multistate Output MV...

Страница 10: ...ured to do so then the new value will be available to be polled in any moment from the ASCII enabled device connected to this ASCII interface This behaviour of sending or not through the ASCII interfa...

Страница 11: ...Multistate Input Loop Accumulator Analog Output Binary Output Multistate Output Analog Value Binary Value Multistate Value Spontaneous Determines if any change of value for the point received from BA...

Страница 12: ...se to indicate that this is a reading message configurable from the configuration tool r Carriage return character HEX 0x0D DEC 13 Message to write a point s value ASCII_String vv r Where Characters D...

Страница 13: ...rtA BACnet MSTP Connect the EIA485 bus to connectors A3 A A4 B and A1 or A2 SNGD of gateway s PortA Respect the polarity PortB ASCII Serial Connect the EIA485 bus to connectors B1 B B2 A and B3 SNGD o...

Страница 14: ...the port marked as Port B of Intesis Connect the EIA485 bus to connectors to connectors B1 B B2 A and B3 SNGD of gateway s PortB Respect the polarity Remember the characteristics of the standard EIA4...

Страница 15: ...and in each end of the bus it must be a termination resistor of 120 Set port switch SW1 to ON if gateway is installed on one bus end SW2 3 will generally go to ON polarization active unless there is a...

Страница 16: ...esis gateway Mini USB cable to connect to PC Link to download the configuration tool Product documentation 5 2 Intesis MAPS Configuration monitoring tool for Intesis ASCII series 5 2 1 Introduction In...

Страница 17: ...nnection parameters Three subsets of information are shown in this window General Gateway general parameters ASCII ASCII interface configuration and BACnet Client BACnet interface parameters Figure 5...

Страница 18: ...tom string commands Define the special character to be used to read or write the internal gateway datapoint Port TCP port to be used for the ASCII communication By default it is set to 5000 Keep Alive...

Страница 19: ...owing parameters should be configured 1 Mode Select whether Intesis is going to connect with BACnet IP or BACnet MSTP Rest of parameters in the section will be different depending on this 2 Mode IP UD...

Страница 20: ...ss Address MSTP Depending on which option is chosen different parameters will appear to enter the details of the address 3 Recipient type Device Object Instance Instance number of device object for th...

Страница 21: ...Instance Search will be based on Device object instance number of present devices in the network Search can be done on all possible Instances 0 to 4194302 or narrowed down until even a single device...

Страница 22: ...net Explorer Exploration of the bacnet network will start once the window BACnet Explorer itself is open You can Stop and restart it button Stop becomes Start in order to stop scanning traffic in the...

Страница 23: ...of objects and devices to integrate In the example above if Apply button is pressed two devices will be integrated Device INBACSAM O000 200 Device INASCBAC 0000 246 The BACnet objects that will be in...

Страница 24: ...ect Instances its corresponding ASCII register and other main parmaters are listed in the signals tab More information on each parameter and how to configure it can be found in the Intesis MAPS user m...

Страница 25: ...ools connection with the Gateway is required The Diagnostic section is composed by two main parts Tools and Viewers Tools Use the tools section to check the current hardware status of the box log comm...

Страница 26: ...c or just 24 Vac Take care of the polarity of the supply voltage applied WARNING In order to avoid earth loops that can damage Intesis and or any other equipment connected to it we strongly recommend...

Страница 27: ...network Button B Reserved for future use Operation Temperature 0 C to 60 C Ethernet 1 x Ethernet 10 100 Mbps RJ45 2 x Ethernet LED port link and activity Operational Humidity 5 to 95 no condensation...

Страница 28: ...hts reserved This information is subject to change without notice URL https www intesis com 28 28 7 Dimensions Recommended available space for its installation into a cabinet wall or DIN rail mounting...

Отзывы: