HMS EC71330 00MA Скачать руководство пользователя страница 25

This page intentionally left blank

Содержание EC71330 00MA

Страница 1: ...Ewon Cosy INSTALLATION GUIDE IG 0031 00 1 0 en US ENGLISH...

Страница 2: ...ible applications of the product and because of the many variables and requirements associated with any particular implementation HMS Networks cannot assume responsibility or liability for actual use...

Страница 3: ...wer Supply 5 3 3 Applicable Directives Standards and Compliance 5 3 4 Field Implementation Environmental Conditions 5 3 5 Internal Battery 9 4 Hardware Description 11 4 1 Label 11 4 2 Overall Descript...

Страница 4: ...Ewon Cosy Installation Guide IG 0031 00 1 0 en US B Specification of the External Power Supply 20 C Digital Output Digital Inputs 21 C 1 Possible Features 22...

Страница 5: ...won biz support 1 2 Document History Version Date Description 1 0 2020 01 08 First release 1 3 Related Documents Document Author Document ID eBuddy HMS AUG 0063 00 Connect an Ewon device to Talk2M HMS...

Страница 6: ...bps Digital Input 2 Digital Output 1 Mounting Latch for DIN rail EN50022 compliant 2 3 Typical Applications The Ewon Cosy can be used for remote access of Ethernet and or USB devices using Talk2M conn...

Страница 7: ...Restriction This equipment is not suitable for use in locations where children are likely to be present 3 4 2 Ingress Protection The Ewon Cosy has an IP20 protection grade Therefore the Ewon Cosy is N...

Страница 8: ...DIN rail mounting position Description 1 SIM card slot 2 DIN rail mounting bracket Fig 2 Wall mounting position Description 1 SIM card slot 2 Wall mounting bracket suggested screw dimensions 4 2 x 32...

Страница 9: ...a free gap of at least 2 cm must be respected in front of all upper lower ventilation openings of the unit A free gap of at least 1 cm must be respected on each side of the unit Fig 3 Free gap surroun...

Страница 10: ...Safety Environmental Regulatory Information 8 24 Ewon Cosy Installation Guide IG 0031 00 1 0 en US...

Страница 11: ...torage Humidity 10 to 95 non condensing Storage Altitude Up to maximum 3000m In any other mounting position than the one explained above the specified operating temperature has to be derated to 25 C t...

Страница 12: ...use several internal burns in just 2 hours and can lead to death If the equipment s enclosure do not close securely stop using the product and keep it away from children If you think batteries might h...

Страница 13: ...ments Marks CE UL logos if applicable The applicable marks on the Ewon Cosy are the following Marks Description Conformit Europ enne or European Conformity EC UL Listed Underwriters Laboraties FCC Fed...

Страница 14: ...XXXXX Label Description Cosy The device is labeled as Ewon Cosy Model XXXXX A unique hardware identifier of the product for certification purposes 4 2 Overall Description 4 2 1 Front Fig 6 Front pane...

Страница 15: ...tch Specifications 4 3 1 Boot Process After powering on or requesting a reboot of the Ewon Cosy a wait is required to get the LAN switch feature fully operational approximately 2 to 4sec The Cosy shou...

Страница 16: ...Ewon Cosy companion tool eBuddy which can be downloaded from www ewon biz support Connect a LAN port port 1 is always set as a LAN port of the Ewon Cosy to one s computer either through a point to po...

Страница 17: ...an Ewon device to Talk2M from Related Documents p 3 The Embedded Wizard Setup If your Ewon Cosy hasn t been configured yet a configuration wizard will be proposed which sets the basics settings of th...

Страница 18: ...seconds until the USR LED blinks red 1x per second If it isn t released at that specific moment a second level reset phase is initiated The LED labeled BI1 turns off Wait approximately 30 seconds unti...

Страница 19: ...error pattern occurs on the USR LED please check out the troubleshooting page www ewon biz support 6 3 Impact Matrix of a Reset Reset level Erased or Reset Preserved Impact of a reset level 1 User res...

Страница 20: ...This page intentionally left blank...

Страница 21: ...e absence of a torque wrench a soft manual tightening is sufficient Fig 9 Connector pinout PIN ICON ID Description 1 O DO_COM Output signal 0V ground connected to the emitter of the MOSFET transistor...

Страница 22: ...should be separately certified according to UL IEC 62368 1 with ES1 PS2 output or separately certified to IEC UL60950 1 with LPS output or Class2 per NEC Characteristics of the power supply can be fo...

Страница 23: ...ocoupler The maximum current flow inside this transistor has a value above the one specified in the Cosy in order to cope with the switching power losses The transistor used is in an open drain type w...

Страница 24: ...tive remote connection remote user connected Here is a summary of the DO status based on Talk2M connectivity T2M LED off DO off There is no VPN tunnel established T2M LED steady DO off The VPN tunnel...

Страница 25: ...This page intentionally left blank...

Страница 26: ...last page 2021 HMS Industrial Networks Box 4126 300 04 Halmstad Sweden info hms se IG 0031 00 1 0 en US 2021 04 30 22283...

Отзывы: