Configuration 3-7
© 2002 HMS Industrial Networks
Document Id:
SCM-7801-026
J1939 Network Configuration
The J1939 network configuration contains the parameters used by the AnyBus-X
for J1939 address management and other network interface options. The parame-
ters are described in Table 3-2 below. Refer to Figure 3-1 to see how each param-
eter is displayed on the user interface.
Parameter
Description
Allowable
Range
Device NAME
The J1939 NAME to be used by the module in
address claim messages.
Each J1939 module should have a unique
NAME.
See the section “Setting the J1939 NAME”
below for details on how the NAME is config-
ured.
See the
J1939-81
specification.
Network Address
List
The list of addresses that the module is able to
use on the J1939 network.
The module will only claim a single address at
a time. This is the list of possible addresses
that it can use if it is unable to claim the first
address.
See “Address Management” on page 6-1 for
details on how the address list is used.
Each address
must be in
the range 1-
253.
Up to 10
addresses
may be in the
list.
Enable Bus-Off
CAN Reset
If this option is enabled, the module will reset
the CAN controller and attempt to go back
online after a bus-off condition is detected.
If the option is disabled, the module will
remain offline after a bus-off condition until it
is power cycled.
For most applications, this option should be
left disabled.
Enabled or
Disabled
Table 3-2 J1939 Network Configuration Parameters