![HMS Anybus X-gateway CANopen Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/hms/anybus-x-gateway-canopen/anybus-x-gateway-canopen_user-manual_2141720045.webp)
43 (60)
Enabling Live List in Anybus Configuration Manager
The Live List feature is available in Object 0x3003 (Live List Enable) in
Anybus Configuration
Manager CANopen
. The feature is disabled by default and is enabled by setting the parameter
Object Value:Value
to
1
.
Fig. 26
Anybus Configuration Manager CANopen
I/O Assembly Examples
Data to Primary Network with Live List Disabled
Byte
Content
0–7
Status word Status word
Data
Data
Data
Data
Data
Data
8–15
Data
Data
Data
Data
Data
Data
Data
Data
Data to Primary Network with Live List Enabled
Byte
Content
0–7
Status word Status word
Nodes
ALL, 1...7
a
Nodes 8...15
Nodes
16...23
Nodes
24...31
Nodes
32...39
Nodes
40...47
8–15
Nodes
48...55
Nodes
56...63
Nodes
64...71
Nodes
72...79
Nodes
80...87
Nodes
88...95
Nodes
96...103
Nodes
104...111
16–23
Nodes
112...119
Nodes
120...127
Data
Data
Data
Data
Data
Data
24–31
Data
Data
Data
Data
Data
Data
Data
Data
a.
If all monitored nodes are in OPERATIONAL state this bit will be 1, else it will be 0.
Anybus
®
X-gateway
™
CANopen
®
PROFINET
®
IRT (2.32) User Manual
SCM-1202-029 1.2 en-US
Содержание Anybus X-gateway CANopen
Страница 60: ...This page intentionally left blank...