Web Interface   

4-6

Slave Status

This page shows status information for each slave device on the USS network.

• Dev

Device address.

• Operational

Device status (e.g. ‘Operational’, ‘Non-Opera-
tional’, ‘Not Present’ etc.).

• PKW  Size

Size (in words) of Parameter Data (PKW) as-
sociated with the slave device.

• PZD  Size

Size (in words) of Process Data (PZD) associ-
ated with the slave device.

View Process Data of Operational Slaves

This page can be used to monitor the Process Data 
(PZD) of all operational slaves on the USS network. 
All data is represented as an array of words in hexa-
decimal format.

Содержание Anybus Communicator PROFINET-USS

Страница 1: ...an Sweden U S A 49 721 96472 0 81 45 478 5340 46 35 17 29 20 1 773 404 3486 ge sales hms networks com jp sales hms networks com sales hms networks com us sales hms networks com User Manual Anybus Comm...

Страница 2: ......

Страница 3: ...formation 2 3 Slave Status Register 2 3 Process Data PZD 2 3 Parameter Data PKW 2 3 Chapter 3 Network Configuration General Information 3 1 TCP IP Settings 3 1 SMTP Account Setting 3 1 Station Name 3...

Страница 4: ...cs 4 5 General 4 5 Identification and Status 4 5 Slave Status 4 6 View Process Data of Operational Slaves 4 6 Appendix A Anybus IPconfig HICP General A 1 Operation A 1 Appendix B Connector Pin Assignm...

Страница 5: ...applications of this product Those responsible for the use of this device must ensure that all the necessary steps have been taken to verify that the application meets all performance and safe ty requ...

Страница 6: ...Changes 1 00 1 01 Revision List Document Author Change Page s Removed redundant section Gateway Status Register Misc minor corrections and adjustments Revision Date Author Chapter s Description 1 00 2...

Страница 7: ...et refers to all data associated with a slave Hexadecimal values are written in the format 0xNNNN where NNNN is the hexadecimal value Support HMS Sweden Head Office E mail support hms networks com Pho...

Страница 8: ...rver allows monitoration of data through an easy to use web based user interface Additionally a built in email client can issue email messages as the status of the slaves on the USS net work changes F...

Страница 9: ...Interface DB9F E Power Supply Input See also B 1 Power Connector C 1 Technical Specification F DIN rail Mechanism The DIN rail mechanism works as follows To snap the gateway on first press the it dow...

Страница 10: ...or Configuration Mismatch Red 3 flashes No Station Name or invalid TCP IP configuration Red 4 flashes Internal error 3 Link Activity Off Ethernet link established Green Transmitting receiving data on...

Страница 11: ...ed to access PKW data must be implemented entirely on the PLC side See also 2 2 USS Master Implementation 2 3 Slave Data Set 3 4 USS PROFINET Configuration SIMATIC Manager 4 1 Web Interface 4 3 Master...

Страница 12: ...that the parameter access protocol used to access PKW data if required must be implemented entirely on the PLC side Configuration The gateway can be configured solely using the PROFINET Configuration...

Страница 13: ...This bit is set 1 if the node is configured in the master or cleared 0 if not configured Slave No USS slave address 0 31 Process Data PZD This is the actual Process Data PZD image Parameter Data PKW T...

Страница 14: ...ettings can also be accessed via the web based configuration interface When using DHCP the gateway will attempt to retrieve the TCP IP settings from a DHCP server dur ing startup If no DHCP server is...

Страница 15: ...ometimes not in cluded in a typical Step 7 installation In such case it is also possible to use a built in function called Edit Ethernet node see 3 3 SIMATIC Manager Edit Ethernet Node To specify the...

Страница 16: ...MATIC Primary Setup Tool To specify the Station Name using the SIMATIC Manager perform the following steps 1 Open the SIMATIC Manager 2 Select the Edit Ethernet Node entry in the PLC menu 3 Select the...

Страница 17: ...tings are properly configured Step 1 Set Up and Add the Gateway to the Configuration To configure the gateway perform the following steps 1 Open the SIMATIC Manager and start a new project 2 Select Se...

Страница 18: ...baudrate for the USS communication perform the following steps 1 Highlight the gateway in the network configuration HW Config window A 2 Right click on slot 0 B and select Object Properties 3 Select...

Страница 19: ...d 2 Select the Insert Object entry 3 Select an object which matches the data sizes PKW and PZD of the slave which shall be added 4 Repeat steps 1 3 for all USS slaves which shall be included in the co...

Страница 20: ...following steps 1 Open a web browser e g Mozilla Firefox 2 Enter the IP address of the gateway in the address field The gateway will ask for authentication The username is USS Gateway and the password...

Страница 21: ...o 4 3 Master Configuration E Mail Notification Settings See also 4 4 E Mail Notification Settings IP Address Settings This page provides access to basic network settings i e IP address subnet mask etc...

Страница 22: ...ion tool see 3 5 Step 2 Specify the Baudrate for the USS Network Data bits fixed to 8 Start bits fixed to 1 Stop bits fixed to 1 Parity fixed to even Master Configuration This page presents an overvie...

Страница 23: ...ication Setup Specifies which slaves that shall trigger email status notifications to enable notification for a par ticular slave check the corresponding checkbox To disable notification for a slave u...

Страница 24: ...nd Status This page displays information about the gateway as well as the general status of the USS network this information may be useful when contacting HMS support services Gateway Name Profinet Ga...

Страница 25: ...al Not Present etc PKW Size Size in words of Parameter Data PKW as sociated with the slave device PZD Size Size in words of Process Data PZD associ ated with the slave device View Process Data of Oper...

Страница 26: ...e network can be rescanned at any time by clicking Scan In the list of detected devices the gateway will by default appear as ABC PRT USS To alter the network settings of the gateway double click on i...

Страница 27: ...inated to PE via a filter circuit 5 6 RD 7 Normally left unused to ensure signal integrity these pins are tied together and terminated to PE via a filter circuit 8 Pin Signal Notes 1 24VDC 2 GND Pin S...

Страница 28: ...27 mm L x W x H inches 4 72 x 2 95 x 1 06 L x W x H Electrical Characteristics Power Supply Power 24V 10 Power Consumption Maximum power consumption is 280mA Typically around 100 mA Environmental Cha...

Страница 29: ...e with the following standards EN 50082 2 1993 EN 55011 1990 Class A EN 61000 6 2 1999 EN 61000 4 3 1996 10V m EN 61000 4 6 1996 10V m all ports EN 61000 4 2 1995 8kV Air Discharge 4kV Contact dischar...

Страница 30: ......

Отзывы: