HMS Anybus AB7702 Скачать руководство пользователя страница 2

Important User Information

Liability

Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of any
inaccuracies or omissions. The data and illustrations found in this document are not binding. We, HMS Industrial
Networks AB, reserve the right to modify our products in line with our policy of continuous product development.
The information in this document is subject to change without notice and should not be considered as a commit-
ment by HMS Industrial Networks AB. HMS Industrial Networks AB assumes no responsibility for any errors that
may appear in this document.

There are many applications of this product. Those responsible for the use of this device must ensure that all the
necessary steps have been taken to verify that the applications meet all performance and safety requirements in-
cluding any applicable laws, regulations, codes, and standards.

HMS Industrial Networks AB will under no circumstances assume liability or responsibility for any problems that
may arise as a result from the use of undocumented features, timing, or functional side effects found outside the
documented scope of this product. The effects caused by any direct or indirect use of such aspects of the product
are undefined, and may include e.g. compatibility issues and stability issues.

The examples and illustrations in this document are included solely for illustrative purposes. Because of the many
variables and requirements associated with any particular implementation, HMS Industrial Networks AB cannot as-
sume responsibility for actual use based on these examples and illustrations.

Intellectual Property Rights

HMS Industrial Networks AB has intellectual property rights relating to technology embodied in the product de-
scribed in this document. These intellectual property rights may include patents and pending patent applications in
the USA and other countries.

Trademark Acknowledgements

Anybus

®

is a registered trademark of HMS Industrial Networks AB. All other trademarks are the property of their re-

spective holders.

Copyright © 2016 HMS Industrial Networks AB. All rights reserved.

Anybus

®

Modbus-TCP/RTU Gateway User Manual

HMSI-168-77 3.0

Содержание Anybus AB7702

Страница 1: ...Anybus Modbus TCP RTU Gateway USER MANUAL HMSI 168 77 3 0 ENGLISH...

Страница 2: ...ity for any problems that may arise as a result from the use of undocumented features timing or functional side effects found outside the documented scope of this product The effects caused by any dir...

Страница 3: ...t history 3 1 3 Conventions 4 1 4 Terminology 4 2 Introduction 5 3 Installation 6 3 1 Mounting on DIN Rail 6 3 2 MAC ID and Default IP Address 6 3 3 Connections 7 3 4 LED Indicators 8 4 Configuration...

Страница 4: ...This page intentionally left blank...

Страница 5: ...site at www anybus com support 1 2 Document history Summary of recent changes Change Where section no Major rewrite Revision list Version Date Author Description 1 00 1 13 2 00 2009 10 09 KeL New temp...

Страница 6: ...onfiguration scripts This is a cross reference within this document Conventions p 4 This is an external link URL www hms networks com This is additional information which may facilitate installation a...

Страница 7: ...o the virtual slave of the Anybus Modbus TCP RTU Gateway will be forwarded to the Modbus RTU network The maximum frame length number of registers that can be used is limited only by the Modbus specifi...

Страница 8: ...tly downwards 2 Pull the bottom end of the unit free of the rail and lift the unit from the rail 3 2 MAC ID and Default IP Address The default IP address of a Anybus Modbus TCP RTU Gateway is 10 200 1...

Страница 9: ...mmon 19 NC Not used 18 NC Not used 17 RS232 RX RS 232 Receive 16 RS232 TX RS 232 Transmit 15 COM Serial common signal ground 14 RS 485 A RS 485 Line A 13 RS 485 B RS 485 Line B 3 3 2 D sub Connector T...

Страница 10: ...er Green System is operating normally Orange System is starting up Red Hardware fault Flashing red Error during initialization Serial Link Flashing green Receiving serial packet on either port Flashin...

Страница 11: ...ble file to run the installer 4 1 2 Scanning for Connected Devices Make sure that the devices to be configured are connected on the same Ethernet subnet as the computer running IPconfig Use standard E...

Страница 12: ...ters a z A Z 0 9 and _ underscore are allowed The default password for authentication of the new settings is admin To change the password check the Change password box and enter the current password i...

Страница 13: ...DHCP but there is no DHCP server on the network the device may no longer be detected in a scan To recover the device an internal DHCP server in IPconfig can be activated Click the checkbox to enable...

Страница 14: ...ssword should be changed after the first login The user name cannot be changed 4 2 1 Network Fig 13 Network settings The Network settings page allows viewing and changing the TCP IP settings These are...

Страница 15: ...the next If set to 0 zero the default Modbus setting of 3 5 characters is used The actual time will then depend on the baud rate Ethernet Settings Modbus TCP Port Number The port to use for Modbus TCP...

Страница 16: ...ng Modbus RTU responses Buffer Overruns Input buffer overruns incoming Modbus RTU responses that are exceeding 300 bytes Exception Responses Exception responsed from connected Modbus RTU slaves 4 2 4...

Страница 17: ...xceptions responses 0 65535 Can be cleared Serial status internal requests and web pages 17 Valid responses 0 65535 Can be cleared 18 Serial time outs 0 65535 Can be cleared 19 CRC errors 0 65535 Can...

Страница 18: ...byte of IP address 34 Valid IP address 4 0 255 Enabled Fourth byte of IP address 35 Mask for Valid IP address 1 0 255 Enabled First byte of mask 36 Mask for Valid IP address 2 0 255 Enabled Second by...

Страница 19: ...s Modbus RTU ASCII TCP Baud rates 300 115200 bps Mounting DIN rail EN 50022 Housing Grey plastic LEXAN 940 Self extinguishing accord ing to UL94 V0 Dimensions W x D x H 90 x 70 x 58 mm Operating tempe...

Страница 20: ...6 4 2007 Emission standard for industrial environment EN 55016 2 3 Class A 2010 EN 55022 Class A 2011 EN 61000 6 2 2005 Immunity for industrial environment EN 61000 4 2 2009 EN 61000 4 3 2006 EN 6100...

Страница 21: ...This page intentionally left blank...

Страница 22: ...last page HMSI 168 77 3 0 UTC 2016 HMS Industrial Networks AB...

Отзывы: