Mounting the Wireless Router on the Starterkit 

Unpack the starterkit from the transport case. 

Mount the wireless router on the DIN rail for the starterkit (to the left side of the starterkit). Make sure that 

the antenna connectors are on the top and power connector on the bottom. 

Power Supply 

With the starterkit a power supply kit is delivered as well. 

 

Mount the appropriate mains power adaptor for your region. 

 

Mount the M12 connector of the power cable to the X31 port of the orange IO-Link Master. 

 

Mount the orange power connector to the small gateway between the wireless router and the IO-Link 

master. 

 

Mount the white power connector to the wireless router. 

 

Connect the power supply to a mains outlet (230 VAC or 110 VAC) 

Antennas 

Antennas are connected to the SMA connectors of the device. 

Mount two stub antennas on the wireless router. These two antennas should be connected to the ports 

marked Cellular 1 and Cellular 2. 

For the Wireless Router 5G 4 antennas are needed in order to achieve 3GPP compliance. In this case the 

additional two antennas should be connected to the ports marked GNSS and Cellular 3. 

Connecting Ethernet 

Two Ethernet cables are supplied with the starterkit. 

One Ethernet cable has an M12 connector. The M12 connector should be connected to the X22 port on the 

Orange IO-Link Master. The other end is connected to port 1 on the wireless router. 

The other Ethernet cable is connected to Eth1 of the small gateway next to the IO-Link master (Eth1 is the 

top one). The other end of the cable is connected to port 2 of the wireless router. 

Test the Sensors 

At this stage it is possible to test the sensors. 

When idle the stack light should be displaying different "standby" patterns. 

Содержание 5G Starterkit with IO-Link sensors

Страница 1: ...5G Starterkit User Guide Revision 1 1...

Страница 2: ...his use cases Mobile Worker The mobile worker use case is key part of the digitalization of the factory In this demo the mobile worker will be provided sensor data through a dashboard on a tablet In a...

Страница 3: ...bile control panels with safety Mobile robots Massive wireless sensor networks Addressed by this demo Remote access and maintenance Augmented reality Addressed as Mobile Worker by this demo Closed loo...

Страница 4: ...ct private cellular network In addition you will need the following during configuration A laptop with an Ethernet cable PH2 screwdriver for mounting the SIM Inserting the SIM in the Wireless Router T...

Страница 5: ...ected to the SMA connectors of the device Mount two stub antennas on the wireless router These two antennas should be connected to the ports marked Cellular 1 and Cellular 2 For the Wireless Router 5G...

Страница 6: ...or the stack light will switch mode and instead show an indication of the distance When the push button is pressed the stack light will show the signal strength of the wireless router In case signal s...

Страница 7: ...browser The default credentials are Username admin Password admin Optional Factory Reset Factory reset of the device can be performed by inserting a paper clip or similar into the small hole in the f...

Страница 8: ...rmally be left empty Network type This setting can usually be left on Auto Alternatively a specific technology can be chosen E g LTE NR5G which indicates a 5G non standalone system After the parameter...

Страница 9: ...dashboard from the tablet port forwarding must be configured in the wireless router Go to Home Security Port Forwarding in order to configure port forwarding Please configure forwarding of port 80 TC...

Страница 10: ...be removed The SD Card is located close to the power connector The Dashboard Application Software can be found on https www hms networks com technologies 5G 5G solutions starterkits Insert the SD Car...

Страница 11: ...nsor and other sensor data http IP address snmpSignal strength PLC Integration Normally the IO Link devices are controlled by the small gateway next to the orange IO Link master As an alternative to t...

Страница 12: ...nk master has a dedicated Ethernet port for IT connectivity In order to connect to this port an extra M12 RJ 45 Ethernet cable is needed This cable can be ordered from IFM with article number E12490 C...

Отзывы: