JSON Files
The json files mentioned in the previous section "Custom Dashboard" can also be used for IT integration. In
this case the IT system simply reads the json files periodically in order to get the data from the sensors.
Modbus/TCP
It is also possible to read the sensor data directly from the orange IO-Link master. This is done in a similar
way as for "PLC Integration" described above.
If Modbus data are only read by the IT system it is not necessary to disconnect the small gateway next to
the orange IO-Link master.
MQTT or REST API
The orange IO-Link master has a dedicated Ethernet port for IT connectivity. In order to connect to this port
an extra M12/RJ-45 Ethernet cable is needed. This cable can be ordered from IFM with article number
E12490.
•
Connect an M12/RJ-45 Ethernet cable between the IO-Link Master port X23 to the Wireless Router
port 3.
•
IO-Link device data is available as MQTT and REST API from the IO-Link master. Please see the IFM
support web pages regarding information how to configure the IO-Link master and how to access the
data through MQTT and REST API.
•
In order to enable MQTT and REST API connectivity through the 5G network the Wireless Router 5G
needs to be configured. Please see the user manual provided on
networks.com/technologies/5G/5G-solutions-starterkits