HME ZOOM Nitro Скачать руководство пользователя страница 2

© 2022 HM Electronics, Inc. All rights reserved.

2

10. Mount the TSP60 using the three mounting 

keyholes at the rear of the unit. The two lower 
keyholes can be accessed by opening the lower 
front cover of the housing.  The latch is magnetic, 
use the finger tabs on both sides and pull back 
from the housing to open (see Fig. 2.1). 
•  Use the TSP Template image on the last page 

of this guide to punch through and mark all 
three mounting keyholes on the wall (the top 
hole cannot be accessed through the TSP 
housing).

•  Drill three holes at the marked locations.
•  Install the provided hardware (screws and 

wall anchors if necessary) but do not tighten 
the screws. Leave a gap (~ ¹/8th inch (3.2 
mm)) between the screw heads and wall.

3”

(76.2 mm)

W

ALL

FINGER TAB

(both sides)

PULL To OPEN

TSP 60

SIDE VIEW

TSP60

SIDE VIEW

CLOSED                                                        OPENED

SCREW

(x3)

ANCHOR

(x3)

Fig. 2.1

•  Align the keyholes to the screw heads.
•  Mount the TSP60 over all three screw heads 

until flush against the wall, then slide down 
onto the screw shanks to secure it in place.

11. Route and terminate component cables to the 

TSP60 through the opening on the rear housing. 
Refer to the TSP Wiring Connections and Fig. 3.1 
on page 3 while following these next few steps.

12. 

Connecting Loop Detectors

:

After the Base Station has been connected to 
the TSP, connect the first loop detector cable to 
the LOOP1 connector (J4) of the TSP using Red 

and Black wires. These may be connected in any 
order (see Fig. 2.4). Any additional loops after 
the menu point, such as a pickup window or a 
pull-forward spot, can be connected to LOOP2, 
3, and 4 connectors (J5, J6, and J7), respectively. 

Note:

 Activation is required to use LOOP2 - 4.

13. When connecting a base station, choose one of 

the following steps: A, if connecting a NEXEO|H-
DX™ Base Station to the TSP, or B, if connecting 
an EOS|HD

®

 Base Station to the TSP. Also, refer 

to Fig. 3.1 wiring connections on page 3.

A   For NEXEO: Connect the Green and White 

wires from J800-1&2 on the base station to 
the Greet1 terminals J1-1&2 on the TSP (see 
Fig. 2.2). With polarized terminals, always 
cve to +ve and -ve to -ve. Connect 
the Shield wire to ground (pin 5 on J800 & 
J1). Connect the remaining Red wire from 
J800-7 to J2-1 and Black wire from J800-6 to 
J2-2 (or any of the available detector inputs). 
For stores with another menu (e.g., a Y-Lane), 
repeat this step using J801 on the base sta-
tion to Greet2 and another detector input on 
the TSP.

8      7      6      5

      4       3       2      1

8      7      6      5

      4       3       2      1

1      2      3      4

      5       6       7      8

1      2      3      4

      5       6       7      8

NEXEO

Base Station

J801

    LANE 2 TIMER

J800

    LANE 1 TIMER

ZOOM 

Nitro

TSP60

J2

       EXT. DETECTOR INPUTS

J1

            GREET INPUTS

8      7      6      5

      4       3       2      1

8      7      6      5

      4       3       2      1

1      2      3      4

      5       6       7      8

1      2      3      4

      5       6       7      8

NEXEO

Base Station

J801

    LANE 2 TIMER

J800

    LANE 1 TIMER

ZOOM 

Nitro

TSP60

J2

       EXT. DETECTOR INPUTS

J1

            GREET INPUTS

Fig. 2.2

B   For EOS: Connect the Green and White 

wires from J6-7&8 on the base station to the 
Greet1 terminals J1-1&2 on the TSP (see Fig. 
2.3). With polarized terminals, always con-
nect +ve to +ve and -ve to -ve.  Connect the 

Shield wire to ground on both ends. Connect 
the remaining Red wire from J1-4 to J2-1 
and Black wire from J1-3 to J2-2 (or any of 
the available detector inputs). For stores with 
another menu (e.g., a Y-Lane), repeat this 
step (for Greet 2 and Menu 2) and connect to 
Greet2 and another detector input on the TSP.

1      2      3      4

      5       6       7      8

1      2      3      4

      5       6       7      8

1      2      3      4

      5       6       7      8

1      2      3      4

      5       6       7      8

EOS

Base Station

J6

       MIC AND SPEAKER

J1

       MENU DETECT OUTPUT

ZOOM 

Nitro

TSP60

J2

       EXT. DETECTOR INPUTS

J1

            GREET INPUTS

1      2      3      4

      5       6       7      8

1      2      3      4

      5       6       7      8

1      2      3      4

      5       6       7      8

1      2      3      4

      5       6       7      8

EOS

Base Station

J6

       MIC AND SPEAKER

J1

       MENU DETECT OUTPUT

ZOOM 

Nitro

TSP60

J2

       EXT. DETECTOR INPUTS

J1

            GREET INPUTS

Fig. 2.3

14. 

Connecting  the USB cable:

Connect the USB type B end to the TSP60. 
Connect the other end to the Black (bottom) 
USB port on the front panel of the CU60. The 
TSP60 turns on automatically when the CU60 
is powered on (see Fig. 2.4).

A             B                           1            2             3             4                           5             6            7             8

GREET

POWER

EXTERNAL    DETECTORS

ON-BOARD    DETECTORS

TSP60

J8  GREET

J6  EXT. DET IN J10 DET OUT

J4

LOOP5

J5

LOOP6

J6

LOOP7

J7

LOOP8

TSP60

FRONT VIEW

CU60

END VIEW

CO
M

USB type B end

LOOP

DETECTOR

POWER LED turns on

When CU60 is powered on

USB type A end

Fig. 2.4

15. Use cable ties and the strain relief holes on the 

TSP60 rear housing to bundle and strain relief 
the cables exiting the unit at the rear.

16. Turn on the CU60 (if it was not turned on in step 

14) and turn on the monitor using the power 
button. 

17. 

The ZOOM Nitro screen

:

•  When you first boot up the system, the Instal-

lation Wizard screen appears (see Fig. 2.5).

•  The Installation Wizard walks you through 

several screens. Fill in the required informa-
tion to progress to the next screen. For ex-
ample, on the second screen, you must scroll 
through and read EULA page and click on the 
Agree button to advance to the next screen. 
When you reach the Network Settings screen, 
enable “DHCP” to auto-populate the fields. 
Finally, a Congratulations prompt completes 
the Installation Wizard; click Done to exit. The 
Dashboard now appears. 

•  Click the menu icon in the Dashboard’s up-

per left corner, choose the 

SECURITY

 option, 

and log in as the Installer.

•  Use the 

CAR DETECTION SETTINGS o

ption to 

configure system to the store’s layout. Use 
the 

STORE

 

and DASHBOARD SETTINGS

 options 

to customize the system further based on the 
customer’s preference.

Fig. 2.5

18. Your system is now ready for use. 

•  Refer to the ZOOM Nitro User’s Guide for 

details on how to use the system. 

•  If there are any installation issues, call HME 

Technical Support at 1.800.848.4468.

10

11

12

13

15

16

17

14

18

A

B

Отзывы: