HME Clear-Com ProGrid PG2-MADI-C-FX Скачать руководство пользователя страница 7

PG2-MADI-C-FX User Guide                               

 

Device Description 

Optocore TECHNOLOGY

 

Optocore™ is a technology platform for sending large amounts of audio, with very low latency around a fiber-based 
network.  This transport (and management system) is of very high quality, suitable for concerts, recording studios, 
and broadcast applications. SANE™ is a spin-off technology that adapts this same technique to a smaller network 
(Ethernet) and at a lower cost. The SANE connections are used to provide expansion units at any fiber node. 
ProGridinterfaces use both Optocore and SANE technologies to provide a high quality low latency media transport 
system. ProGrid will interface with all other OEM products utilizing the Optocore technology, for example Yamaha, 
DiGiCo and AVID. 

 

The PG2-MADI-C-FX is a digital I/O unit and interface to the ProGrid Signal Transport Solution. The unit provides 
two coaxial optical MADI input and two coaxial MADI output ports, allowing the transmission of up to 128 input and 
128 output digital audio channels. Sample rates up to 192 kHz are possible. Each MADI port can be adjusted by 
OPTOCORE CONTROL software to handle different formats according to the standards AES10-1991/AES10-
2003. BNC coaxial cables are used at the MADI ports.

 

Redundant fiber connections can be established using the two provided SFP based LC multimode optical LINK-
interfaces. The dual redundant ring structure provides maximum safety in a network with an outstandingly low 
latency. It facilitates the use of the advantages of fiber optical transmission in all sorts of temporary and permanent 
applications, especially when long distance connections and high-quality audio are required. 

The PG2-MADI-C-FX enables you to connect to the SANE network via RJ45 ports. It is possible to use SANE as a 
Cat5 based cost-efficient extension to the optical core system. SANE ports may be used as point-to-point MADI 
over Cat5 or as a bridge interface between SANE and Optocore, giving up to 128 input and 128 output channels 
additionally. 

Two built-in Ethernet ports may be used to tunnel 100Mbit Ethernet through the OPTOCORE and SANE networks. 
The PG2-MADI-C-FX together with ProGrid R-Series devices and YG2 behaves like one 100Mbit Ethernet switch. 
SANE ports can be used for Ethernet transport as well, so up to four ports can be used to provide Local Ethernet 
connection via PG2-MADI-C-FX. 

The PG2-MADI-C -FX provides both word clock input and output. It includes bi-directional composite video 
interfaces. Four RS485 ports allow the transport of a wide range of standards such as RS422, DMX, MIDI, and 
CAN-Bus. In addition to the audio signals, video and data signals are transmitted by the fiber connection. The dual

 

power supply unit, with automatic switchover, permits a redundant power supply and safeguards against 
malfunctions of the unit if one power supply fails to run. 

The PG2-MADI-C-FX is the perfect I/O unit for a wide range of professional audio devices with MADI inputs and 
outputs such as digital consoles and I/O systems. The huge amount of channels exchanged by one PG2-MADI-C-
FX makes it the ideal and most cost effective interface for digital console systems. The number of input channels 
can be defined in groups of eight by the OPTOCORE CONTROL software. Only this number of channels is 
allocated for transmission via fiber optical connection. This keeps the system highly flexible in order to build the 
network exactly suiting the applications need. A PG2-MADI-C-FX, for example, can transmit 128 channels to a 
digital console system from various ProGrid devices such as PG32-AES-FX, PG16-FX or PG8-TP. If only eight 
return channels from the console are required, only these eight channels instead of 128 inputs can be received at 
the PG2-MADI-C-FX and transmitted via fiber optical connection, leaving the other channels to be shared by the 
other network devices. Networks with several PG2-MADI-C-FX and other ProGrid devices allow the transport of a 
huge amount of digital data, e.g. 768 audio channels with a sample rate of 48 kHz, 32 RS485 channels and three 
video channels. Depending on the fiber optic transceivers distances from 700 m up to 70 km can be covered. 

The dual optical interfaces with data transfer rates of 2 Gbps are equipped with LC-connectors, commonly used 
and absolutely reliable in permanent installations. 

Due to SMD production the PG2-MADI-C-FX fulfills the demand of highest digital standards occupying only one 

Содержание Clear-Com ProGrid PG2-MADI-C-FX

Страница 1: ...PG2 MADI C FX User Guide PN 399G090 Rev B 10 22 14...

Страница 2: ...ineering No part of this document may be reproduced in any form by any means without prior written authorization of Clear Com an HME Company Clear Com Offices are located in California USA Cambridge U...

Страница 3: ...Rear Panel 11 5 Device Details 12 5 1 Fiber Optic Connection 12 5 2 MADI Ports 12 5 3 SANE Ports 12 5 4 RS485 Auxiliary Ports 12 5 5 Word Clock 12 5 6 Video Ports 13 5 7 Ethernet Ports 13 5 8 Power Su...

Страница 4: ...10 Word Clock Connection 17 8 11 Video Connection 17 8 12 Mains Connection 17 9 Starting Up 18 9 1 Software Installation 18 9 2 ProGrid Network Setup 18 9 3 Hardware Connection 20 9 4 Network Examples...

Страница 5: ...exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus Wh...

Страница 6: ...bols Familiarize yourself with the safety symbols in Figure 1 Safety symbols These symbols are displayed on the apparatus and warn you of the potential danger of electric shock if the system is used i...

Страница 7: ...s The PG2 MADI C FX together with ProGrid R Series devices and YG2 behaves like one 100Mbit Ethernet switch SANE ports can be used for Ethernet transport as well so up to four ports can be used to pro...

Страница 8: ...is used to change the configuration or define own settings It provides easy access to all configuration and control tools including routing naming gain setting and phantom power activation for attach...

Страница 9: ...ED ON Signal present LED OFF No signal present AUDIO LINK Indicates the audio link status SL1 Communication is established via SANE 1 rear panel SL2 Communication is established via SANE 2 rear panel...

Страница 10: ...Ethernet communication is established via SANE 2 rear panel There is other device with physical Ethernet port enabled on the network L1 Ethernet communication is established via LAN 1 rear panel L2 Et...

Страница 11: ...site video MADI 1 2 2 x SC multimode optical MADI inputs and 2 x SC multimode optical MADI outputs POWER 2 Mains input for power supply 2 100 240 V POWER 1 Mains input for power supply 1 100 240 V SAN...

Страница 12: ...smitted on the fiber optical connection can be defined with OPTOCORE CONTROL This keeps the matrix easy to handle and the quantity of channels per device in the network flexible Using one PG2 MADI C F...

Страница 13: ...h over to the other power supply unit In order to make the power supply redundant both power inputs must be connected to the mains supply if possible to different phases power supply systems or even b...

Страница 14: ...ontrol All system and device parameters are set on a PC connected to the device via RS232 or USB port by use of the OPTOCORE CONTROL software Third party protocols for device controlling can be used i...

Страница 15: ...2 Gbit network is as follows Audio 768 Channels 48 KHz RS485 Data 32 Channels Video 3 CVBS Video Channels Ethernet 100 MBit Fast Ethernet If the network is used for the transport of Ethernet compatibl...

Страница 16: ...with RJ 45 connector SANE technology utilizes all 4 pairs of Cat 5 cable two for standard Ethernet transmission two for SANE Maximum distance between two devices connected by SANE is 100m 8 4 Auxilia...

Страница 17: ...User Guide 8 10 Word Clock Connection Use 75 coaxial cable with BNC connector 8 11 Video Connection Use 75 coaxial cable with BNC connector 8 12 Mains Connection Standard power cords with IEC C13 soc...

Страница 18: ...ndling of OPTOCORE CONTROL please refer to the HELP menu of the software We strongly recommend getting familiar with the OPTOCORE CONTROL software 9 2 ProGrid Network Setup Before connecting a PG2 MAD...

Страница 19: ...RS485 SETUP of ID 2 is In which channel data is transmitted to Out which channel is received for each port Port Channel 5 8 Port 3 Channel 4 RS485 Video Ethernet setup In order to use ProGrid for Eth...

Страница 20: ...are previously configured the network is ready to work With a PC connected to any unit in the loop and by running the OPTOCORE CONTROL software the network may be analyzed supervised parameters may be...

Страница 21: ...21 PG2 MADI C FX User Guide 9 4 Network Examples Note Fig 3 Redundant network with two PG2 MADI C FX sending 128 audio channels from console to the recording device and 64 return channels...

Страница 22: ...22 PG2 MADI C FX User Guide Note Fig 4 Redundant network with one PG2 MADI C FX and PG16 FX SANE based stagebox 48 analog inputs and 16 analog outputs are available at the PG16s...

Страница 23: ...acc to 4 40 UNC Pin out RS232 Port Channel RS232 Internally Bridged Power Use 1 modem cable male female to connect to PC RXD TXD 5VS GND Pin 3 2 1 4 6 7 8 9 5 D Sub 9 female 5 1 9 6 Locking system ac...

Страница 24: ...24 PG2 MADI C FX User Guide PG2 MADI C FX Auxiliary Port 4 x RS485 X3 X4 I Os D Sub 9 male Fastening system 4 40 UNC COM RS422 X3 R x D X4 T x D D Sub 9 female Fastening system 4 40 UNC...

Страница 25: ...V Sense level Input 400 mVpp Remote Control Convention RS232 EIA TIA 232 57 600 Baud USB USB 2 0 Device 12 Mbit s LAN TIA 568A B IEEE 802 3 10 100 Mbit s SANE LAN Convention Audio TIA 568A B Optocore...

Страница 26: ...nt panel width 483 mm 19 inch height 44 mm 1 73 inch depth 200 mm 7 87 inch Rear panel width 438 mm 17 25 inch Weight 2 7 kg 4 41 lbs Modifications that serve the purpose of technical improvement of t...

Страница 27: ...his device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le fonctionnement est soumis aux deux condi...

Страница 28: ...ad it is the user s responsibility to dispose of the user s waste equipment by handing it over to a designated collection point for the recycling of WEEE The separate collection and recycling of waste...

Страница 29: ...ine its coverage exclusions from coverage and duration EXCEPT AS SET FORTH IN THE STANDARD LIMITED WARRANTY CLEAR COM MAKES NO WARRANTIES REGARDING THE PRODUCT EXPRESS IMPLIED OR STATUTORY INCLUDING W...

Отзывы: