HME Clear-Com ProGrid PG2-MADI-C-FX Скачать руководство пользователя страница 27

27 

PG2-MADI-C-FX User Guide                               

 

13 

Compliance 

FCC notice 

This device complies with Part 15 of the FCC rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) This device must 
accept any interference received, including interference that may cause undesired operation.  

NOTE: 

This equipment has been tested and found to comply with the limits for a Class A 

digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide 
reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instruction manual, may cause 
harmful interference to radio communication. Operation of this equipment in a residential area 
is likely to cause harmful interference, in which case you will be required to correct the 
interference at his own expense.  

Changes or modifications not expressly approved by Clear-Com, LLC, an HM Electronics, Inc. 
company could void the user’s authority to operate this equipment. 

IC Notice: 

Operation is subject to the following two conditions: (1) this device may not cause 
interference, and

 

(2) this device must accept any interference, including interference that may 

cause undesired

 

operation of the device.

 

Le fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne peut pas 
provoquer d’interférences, et (2) cet appareil doit supporter toute interférence, y compris des 
interférences qui pourraient causer un mauvais fonctionnement de l'appareil. 

Industry Canada Compliance Statement 

This Class[A] digital device complies with Canadian ICES-003. 

Avis de conformité à la réglementation d'Industrie Canada 

Cet appareil numérique de la class[A] est conforme à la norme NMB-003 du Canada. 

The PG2-MADI-C-FX product complies with the following standards: 

EN55022           Emissions 

EN55024           Immunity 

Electromagnetic Compatibility Directive 2004/108/EC 

Low Voltage Directive 2006/95/EC 

Warning:

 

This is a Class A product.  In a domestic environment this product may cause radio 
interference in which case the user may be required to take adequate measures.  

 

Waste Electrical And Electronic Equipment (WEEE)  

The European Union (EU) WEEE Directive (2002/96/EC) places an obligation on producers 
(manufacturers, distributors and/or retailers) to take-back electronic products at the end of 
their useful life. The WEEE Directive covers most Clear-Com products being sold into the EU 
as of August 13, 2005. Manufacturers, distributors and retailers are obliged to finance the 

Содержание Clear-Com ProGrid PG2-MADI-C-FX

Страница 1: ...PG2 MADI C FX User Guide PN 399G090 Rev B 10 22 14...

Страница 2: ...ineering No part of this document may be reproduced in any form by any means without prior written authorization of Clear Com an HME Company Clear Com Offices are located in California USA Cambridge U...

Страница 3: ...Rear Panel 11 5 Device Details 12 5 1 Fiber Optic Connection 12 5 2 MADI Ports 12 5 3 SANE Ports 12 5 4 RS485 Auxiliary Ports 12 5 5 Word Clock 12 5 6 Video Ports 13 5 7 Ethernet Ports 13 5 8 Power Su...

Страница 4: ...10 Word Clock Connection 17 8 11 Video Connection 17 8 12 Mains Connection 17 9 Starting Up 18 9 1 Software Installation 18 9 2 ProGrid Network Setup 18 9 3 Hardware Connection 20 9 4 Network Examples...

Страница 5: ...exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus Wh...

Страница 6: ...bols Familiarize yourself with the safety symbols in Figure 1 Safety symbols These symbols are displayed on the apparatus and warn you of the potential danger of electric shock if the system is used i...

Страница 7: ...s The PG2 MADI C FX together with ProGrid R Series devices and YG2 behaves like one 100Mbit Ethernet switch SANE ports can be used for Ethernet transport as well so up to four ports can be used to pro...

Страница 8: ...is used to change the configuration or define own settings It provides easy access to all configuration and control tools including routing naming gain setting and phantom power activation for attach...

Страница 9: ...ED ON Signal present LED OFF No signal present AUDIO LINK Indicates the audio link status SL1 Communication is established via SANE 1 rear panel SL2 Communication is established via SANE 2 rear panel...

Страница 10: ...Ethernet communication is established via SANE 2 rear panel There is other device with physical Ethernet port enabled on the network L1 Ethernet communication is established via LAN 1 rear panel L2 Et...

Страница 11: ...site video MADI 1 2 2 x SC multimode optical MADI inputs and 2 x SC multimode optical MADI outputs POWER 2 Mains input for power supply 2 100 240 V POWER 1 Mains input for power supply 1 100 240 V SAN...

Страница 12: ...smitted on the fiber optical connection can be defined with OPTOCORE CONTROL This keeps the matrix easy to handle and the quantity of channels per device in the network flexible Using one PG2 MADI C F...

Страница 13: ...h over to the other power supply unit In order to make the power supply redundant both power inputs must be connected to the mains supply if possible to different phases power supply systems or even b...

Страница 14: ...ontrol All system and device parameters are set on a PC connected to the device via RS232 or USB port by use of the OPTOCORE CONTROL software Third party protocols for device controlling can be used i...

Страница 15: ...2 Gbit network is as follows Audio 768 Channels 48 KHz RS485 Data 32 Channels Video 3 CVBS Video Channels Ethernet 100 MBit Fast Ethernet If the network is used for the transport of Ethernet compatibl...

Страница 16: ...with RJ 45 connector SANE technology utilizes all 4 pairs of Cat 5 cable two for standard Ethernet transmission two for SANE Maximum distance between two devices connected by SANE is 100m 8 4 Auxilia...

Страница 17: ...User Guide 8 10 Word Clock Connection Use 75 coaxial cable with BNC connector 8 11 Video Connection Use 75 coaxial cable with BNC connector 8 12 Mains Connection Standard power cords with IEC C13 soc...

Страница 18: ...ndling of OPTOCORE CONTROL please refer to the HELP menu of the software We strongly recommend getting familiar with the OPTOCORE CONTROL software 9 2 ProGrid Network Setup Before connecting a PG2 MAD...

Страница 19: ...RS485 SETUP of ID 2 is In which channel data is transmitted to Out which channel is received for each port Port Channel 5 8 Port 3 Channel 4 RS485 Video Ethernet setup In order to use ProGrid for Eth...

Страница 20: ...are previously configured the network is ready to work With a PC connected to any unit in the loop and by running the OPTOCORE CONTROL software the network may be analyzed supervised parameters may be...

Страница 21: ...21 PG2 MADI C FX User Guide 9 4 Network Examples Note Fig 3 Redundant network with two PG2 MADI C FX sending 128 audio channels from console to the recording device and 64 return channels...

Страница 22: ...22 PG2 MADI C FX User Guide Note Fig 4 Redundant network with one PG2 MADI C FX and PG16 FX SANE based stagebox 48 analog inputs and 16 analog outputs are available at the PG16s...

Страница 23: ...acc to 4 40 UNC Pin out RS232 Port Channel RS232 Internally Bridged Power Use 1 modem cable male female to connect to PC RXD TXD 5VS GND Pin 3 2 1 4 6 7 8 9 5 D Sub 9 female 5 1 9 6 Locking system ac...

Страница 24: ...24 PG2 MADI C FX User Guide PG2 MADI C FX Auxiliary Port 4 x RS485 X3 X4 I Os D Sub 9 male Fastening system 4 40 UNC COM RS422 X3 R x D X4 T x D D Sub 9 female Fastening system 4 40 UNC...

Страница 25: ...V Sense level Input 400 mVpp Remote Control Convention RS232 EIA TIA 232 57 600 Baud USB USB 2 0 Device 12 Mbit s LAN TIA 568A B IEEE 802 3 10 100 Mbit s SANE LAN Convention Audio TIA 568A B Optocore...

Страница 26: ...nt panel width 483 mm 19 inch height 44 mm 1 73 inch depth 200 mm 7 87 inch Rear panel width 438 mm 17 25 inch Weight 2 7 kg 4 41 lbs Modifications that serve the purpose of technical improvement of t...

Страница 27: ...his device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le fonctionnement est soumis aux deux condi...

Страница 28: ...ad it is the user s responsibility to dispose of the user s waste equipment by handing it over to a designated collection point for the recycling of WEEE The separate collection and recycling of waste...

Страница 29: ...ine its coverage exclusions from coverage and duration EXCEPT AS SET FORTH IN THE STANDARD LIMITED WARRANTY CLEAR COM MAKES NO WARRANTIES REGARDING THE PRODUCT EXPRESS IMPLIED OR STATUTORY INCLUDING W...