User Guide | Arcadia® Central Station
5.21
Logic Page
The Arcadia Central Station offers six fully configurable GPIOs, increasing the range and
possible uses of controls and relays.
l
2 x GPIs. These can be used, for example, to allow the station operator to open an audio
route to a Channel using a foot switch, or to route a program feed to a Channel, Group or
beltpack when an on-air light comes on.
l
Up to 10 different audio routes can be generated on each GPI.
l
4 x GPOs. The most common uses for output relays are to turn on an on-air light, connect
to a radio, or send an input to an external audio console.
l
Up to 10 different actions can be generated on each GPO.
l
You can also set up extended control sequences in the
Control Logic
section.
Relays (GPOs) and GPIs are configured in the
Configuration > Logic
page of the Core
Configuration Manager (CCM) and can be viewed and tested on the
Status > Logic
page.
5.22
Setting up GPIOs and Logic Events
5.22.1
Overview
l
2 x GPIs
l
4 x GPOs
l
Unlimited Logic Events
Page 84
Содержание Clear-Com ARCADIA Series
Страница 1: ...User Guide Arcadia Central Station User Guide Part Number PUB 00021 Revision C September 09 2022 ...
Страница 12: ...User Guide Arcadia Central Station 1 2 Connections Page 12 ...
Страница 52: ...User Guide Arcadia Central Station Page 52 ...
Страница 71: ...User Guide Arcadia Central Station Page 71 ...
Страница 83: ...User Guide Arcadia Central Station Page 83 ...
Страница 99: ...User Guide Arcadia Central Station Page 99 ...
Страница 103: ...User Guide Arcadia Central Station 6 5 2 Connection to IP Transceivers and Dante Example 2 Page 103 ...
Страница 104: ...User Guide Arcadia Central Station 6 5 3 Connection to IP Transceivers and Dante Example 3 Page 104 ...
Страница 108: ...User Guide Arcadia Central Station Unregister Page 108 ...
Страница 119: ...User Guide Arcadia Central Station Page 119 ...
Страница 137: ...User Guide Arcadia Central Station 6 Select the left hand option Page 137 ...
Страница 144: ...User Guide Arcadia Central Station Page 144 ...
Страница 146: ...User Guide Arcadia Central Station 14 1 GPIO pinouts GPIO 1 Relay 1 2 Page 146 ...