ASSEMBLY INSTRUCTIONS

Motor Screw

Blade 

Canopy

Mounting Bracket Screw

J-shaped 

slot

Round 

Hole

Black (Hot)

Wire Connector

White (Neutral)
Bare/Green (Ground)

Black

Blue

White

Green

13

14

12

11

WARNING: 

Do NOT 

wire the fan motor to a 

variable-speed (dimmer) 

wall control. 

12. Raise the canopy, ensure the two mounting bracket

screws are aligned with the J-shaped slots in the canopy.

Then turn the canopy in a clockwise direction until the

mounting bracket screws are completely engaged in

the J-shaped slots. Install the two previously removed

mounting bracket screws in the round holes. Securely

tighten all mounting bracket screws.

13. Install the blade to the top side of the motor with 

motor screws previously removed. Tighten with Phillips 

screwdriver (not included). Repeat for each blade.

11. Use wire connectors to connect the fan wires to the 

power supply wires according to the wiring diagram and 

the following instructions:

• Connect the green wire from the downrod and mounting 

bracket to the bare/green (ground) supply wire.
• Connect the white wire from the fan to the white 

(neutral) supply wire.
• Connect the black and blue wires from the fan to the 

black (hot) supply wire.

Important:

 After the connections have been made, the 

wires should be turned upward and pushed carefully 

up into the outlet box. Place the black and white wire 

connections on opposite sides of the outlet box.

14. Remove one of the three fitter plate screws 

preassembled to the fitter plate and loosen the other two 

but do not remove. Connect the 9-pin connector from

the fitter plate to the 9-pin connector from the switch 

housing. Align the keyhole slots in the switch housing with 

the loosened screws in the fitter plate. Turn switch housing 

clockwise and replace the previously removed fitter plate 

screw. Tighten all screws.

Fitter Plate Screw

Fitter Plate

Keyhole Slot

9-pin 

Connector

Switch 

Housing 

Содержание 51637

Страница 1: ...9711 022621 1 56 CEILING FAN Owner s Manual Model 51637 51638 To obtain service please contact the Service Department 1 877 706 3267 8 a m 5 p m Central Monday Friday RATED FOR WET LOCATION ...

Страница 2: ...sion JJ Secondary Support Screw KK Support Washer MM Secondary Spring Washer Unpack your fan and check the contents You should have the following items PACKAGE CONTENTS HARDWARE CONTENTS Note Some extra hardware has been included The quantity listed above is the number required for installation HARDWARE CONTENTS JJ DD TOOLS REQUIRED not included Tools required for assembly Electrical tape Phillips...

Страница 3: ...ing options Downrod Mount is best suited for ceilings 8 ft or higher For taller ceilings you may want to use a longer downrod not included Angle Ceiling Mount is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensure proper blade clearance from the ceiling If using the angle mount check to ensure the ceiling angle is not steeper than 16 C D B A ...

Страница 4: ...le CAN ICES 005 B NMB 005 B This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant ...

Страница 5: ...wall To reduce the risk of fire electric shock or personal injury mount to outlet box marked acceptable for fan support and use mounting screws provided with the outlet box The installation has to be in accordance with the National Electrical Code ANSI NFPA 70 1999 and local codes If you are unfamiliar with the methods of installing electrical wiring seek the services of a qualified licensed elect...

Страница 6: ...provided with the outlet box WARNING To reduce the risk of fire electric shock or personal injury mount to the outlet box marked acceptable for fan support and use the mounting screws and washers provided with the outlet box 3 Remove the 6 Phillips head motor screws from the top part of the motor and set aside for later use 1 Turn OFF the electrical power at the main fuse or circuit breaker DANGER...

Страница 7: ...cket Downrod Pin Downrod Clip Yoke Downrod Set Screw Canopy Braided Cable Yoke Cover Downrod Yoke 7 6 5 6 Slide the downrod into the yoke of the motor assembly align the holes then re install the downrod pin and downrod clip Secure with the two set screws and slide the yoke cover down until it rests on top of the motor assembly Note With wiring extending out of the downrod measure 8 inches of lead...

Страница 8: ...able must make a complete circle around the support brace to secure the fan 10 Tighten the secondary support screw securing the braided cable 9 8 Secondary Support Screw Braided Cable Outlet Box Brace SECONDARY HANGING SYSTEM For installation in the United States Building codes in the U S A do not require installation of a Secondary Hanging System If desired the braided cable can be cut and remove...

Страница 9: ... to the power supply wires according to the wiring diagram and the following instructions Connect the green wire from the downrod and mounting bracket to the bare green ground supply wire Connect the white wire from the fan to the white neutral supply wire Connect the black and blue wires from the fan to the black hot supply wire Important After the connections have been made the wires should be t...

Страница 10: ...n the switch housing Then secure the switch housing cap using the three previously removed switch housing screws 15 16 17 Switch Housing Screw 17 Turn ON the electrical power at the main fuse or circuit breaker and the wall switch Assembly is complete 16 Attach pull chain extension to the pull chain Switch Housing Switch Housing Cap Pull Chain Extension ...

Страница 11: ...effect In cooler weather push the reverse switch right which will result in upward airflow that can help move stagnant hot air off the ceiling area Important Wait for the fan to stop before moving the reverse switch The reverse switch must be set either completely left or right in order for the fan to function correctly If the reverse switch is set in the middle position the fan will not operate 2...

Страница 12: ...h pushed completely left or right Fan will not operate when switch is in the middle 1 Make sure all screws in motor assembly are snug but not overtightened 2 Make sure the screws that attach the blade to the motor are tight 3 Make sure wire connectors are not rattling against each other or against the interior wall of the switch housing 4 Make sure wire connectors are not rattling against each oth...

Страница 13: ...red by this warranty HKC assumes no responsibility whatsoever for fan installation Any service performed by a non licensed electrician will render the warranty invalid HKC s sole responsibility shall be to repair or replace the motor parts or product within the terms stated above HKC shall not be liable for any loss or damage of any kind including any incidental or consequential damages resulting ...

Отзывы: