Use suitable instruments for the refrigerant R410A.

Do not use mineral oils to clean the unit.

Ensure that the recommende dspace is left around the appliance.

The installation must be done by trained and qualified service personnel with reliability according to this 

manual.

Contact service center before installation to avoid the malfunction due to unprofessional installation.

When picking up and moving the units, you must be guidedby trained and qualified person.

Do not use any other refrigerant than R410A.

MAINTENANCE

INSTALLER

INSTALLATION DIMENSION DIAGRAM

INSTALLER

9

HOSM-18UIHN

30cm

Space to the cover

or above

30cm

50cm

(Air inlet side)

or above

or above

Space to the wall

or more

Space to the cover

50cm

200cm

(Air outlet side)

or above

Содержание ASE9U2I-HN

Страница 1: ...ed Air Conditioner HOSM 18UIHN Thank you for choosing our product For proper operation please read and keep this manual carefully If you have lost the Owner s Manual please contact the local agent or...

Страница 2: ...thout displayer the position and shape of the displayer please refer to the real one In line with the company s policy of continual product improvement the aesthetic and dimensional characteristics te...

Страница 3: ...ectric shock Donot spray wateronindoorunit It may cause electric shock ormalfunction After removing the filter do not touch fins to avoid injury Do not use fire or hair dryer to dry the filter to avoi...

Страница 4: ...Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Air Conditioner should be properly grounded Incorrect grounding may cause electric...

Страница 5: ...and outdoor unit should be connected by a professional If the length of power connection wire is insufficient please contact the supplier for a new one Avoid extending the wire by yourself For the ai...

Страница 6: ...turned on or off according to your requir ement automatically please do not turn on or turn off the unit freque ntly otherwise disadvantage effect may be caused to the unit Rated voltage of this air c...

Страница 7: ...clean the air conditioner cabinet The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube Note The above figures are only intended to a simp...

Страница 8: ...d unit B must be corresponding to each other respective Note the above figures are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units that have...

Страница 9: ...p Location Twisting moment N m 35 40 60 65 45 50 70 75 12 19 Diameter mm 9 52 16 15 20 6 18K unit need to be installed the indoor unit Caution Installation Must be Performed in Accordance with the NEC...

Страница 10: ...l Contact service center before installation to avoid the malfunction due to unprofessional installation When picking up and moving the units you must be guidedby trained and qualified person Do not u...

Страница 11: ...its Have the length of refrigerating pipe and refrigerant charge amount been recorded Has the unit been safely grounded Problems Owing to Improper Installation The unit may drop vibrate or make noises...

Страница 12: ...66129920519...

Отзывы: