Window Kit Installation

Your window kit has been designed to fit most standard “Vertical”
and “Horizontal” window applications, However, it may be neces-
sary for you to improvise/modify some aspects of the installation
procedures for certain types of window. Please refer to Fig. 2 & Fig.
2a for minimum and maximum window openings.

Water Tank Safety Feature

This unit is equipped with a full safe switch mechanism which pre-
vents the unit from condensing water in the event the water tank is
accidentally displaced, and/or FULL with water. If this situation
occurs, the WATER FULL indicator light will flash red continuously
until the Drain Tank is correctly positioned and/or emptied.

INSTALLATION

Horizontal

window

Window Slider Kit
Minimum: 67.5 cm (2.22ft).
Maximum: 123 cm (4.04ft).

Fig. 2

Vertical

window

Window Slider Kit
Minimum: 67.5 cm (2.22ft).
Maximum: 123 cm (4.04ft).
Fig. 2a

Manual 01-05Hiyasu Eng  11/3/05  13:29  Página 42

Содержание APH-9A

Страница 1: ...GLISH Safety rules 35 Names of parts 36 Accessories 37 Operation panel 38 Operating 39 40 Installation 41 42 Maintenance 43 Trouble shooting 44 CONTENTS Manual 01 05Hiyasu Eng Cont 11 3 05 13 28 P gin...

Страница 2: ...he unit upright in order to maintain the compressor in a proper condition 5 Be sure to unplug the unit before cleaning 6 The heater must not be located immediately below a socket outlet 7 If the appli...

Страница 3: ...d Filter cover Exhaust air outlet Drain tank Casters Operation cover Grilles horizontal RCU Drain tank Top cover Casters Operation panel Grilles vertical RCU Drain tank Top cover Operation cover Grill...

Страница 4: ...usage ACCESSORIES PARTS PARTS NAME QUANTITY Duct 1 Adaptor A for permanent duct mounting 1 Adaptor B for temporary duct mounting 1 Wall plug 4 Screws 4 Alkaline batteries the unit is not remote contro...

Страница 5: ...e POWER BUTTON Turn ON OFF the unit The temperature is not displayed under FAN and DRY mode LOUVER BUTTON the louver automatically varies the directions of air flow TEMPERATURE SETTING BUTTON setting...

Страница 6: ...idifying operations have been switched off and need switching on again in a short time allow approximately three minutes for the cooling or dehumidifying operations to resume Ensure that the drain tan...

Страница 7: ...ff when the timer off time is achieved 3 Both TIMER ON and TIMER OFF time can be set simultaneously The air conditioner operates to the nearest time for either TIMER ON or TIMER OFF 4 Press ON OFF but...

Страница 8: ...ach the other end of the duct to adaptor B 3 Put the end of duct to a nearby window B PERMANENT 1 Attach one end of the duct to the exhaust air outlet of the mobi le air conditioner According to the a...

Страница 9: ...This unit is equipped with a full safe switch mechanism which pre vents the unit from condensing water in the event the water tank is accidentally displaced and or FULL with water If this situation o...

Страница 10: ...unit 2 UNIT ENCLOSURE Use a lint free cloth soaked with neutral detergent to clean the unit enclosure Finished by a dry clean cloth 3 DRAIN TANK Wash the tank using warm water about 40 C with neutral...

Страница 11: ...e passed Room temperature is higher than the set temperature Heating mode Reset the temperature Room temperature is lower than the set temperature Cooling mode Reset the temperature The automatic over...

Отзывы: