background image

6

HEATER AND RELAY LIGHTS

1.  Heater LED’s: Cycle On When Heaters Are On

 

Small (1/8”) light-emitting diodes (LED’s) are driven by a current sen-

sor (one for each heater in the dryer). They can, in conjunction with 

relay lights explained below, determine if heater(s) are burned out or 

if a relay is at fault.

2.  Relay Lights: Cycle Off When Heaters Are On

 

Large (1/4”) neon lights indicate proper opening and closing of each 

heater relay. When relay lights are “on”, the relays are “open” and no 

power is applied to the heaters (Heater LED’s Off). When relay lights 

are “off”, the relays are “closed” and power is applied to the heaters 

(Heater LED’s On). If one relay light stays “on” while the others are 

off, then that pole is stuck “open” and should be replaced. The heater 

LED’s will still function as normal as they are “double switched”.

NOTE:

  If all relay lights operated normally yet one of the heater LED’s will 

not come on, check the suspected heater with an amp clamp. Normal 

reading should be 9 - 12 amps depending on element size and voltage 

available. If readings indicate no current flowing, then the heater will 

require replacing.

OPERATION

INCREASING THE LIFE OF YOUR WRAP:

The following actions will increase the life of your wrap and help to prevent 
premature failure.

-  Space your mugs at least 2” apart in oven, this will allow for more 
even heating and airfl ow between mugs.  Also this will prevent mugs 
from banging together reducing the life of your wrap.

-  Do not drop or bang mugs with wraps together.  This can cause 
small tears in your wrap leading to tearing of the wrap.

-  Only use on items the wrap is rated for; the standard HMWII is de-
signed for both 11oz and 15oz mugs. Use of these wraps for anything 
else may shorten the life of the wrap and could result in damage such 
as tearing. For unusually sized or shaped items please utilize a wrap 
custom made for your application.

- Sharp fi ngernails and rings can snare/tear a wrap.

If the above procedures are followed and care is taken when handling these 
wraps you should expect to get hundreds of cycles from your HMWII.

7

OPERATION

ON/OFF POWER BREAKER

IN/OUT (I/O)
CIRCUIT BREAKERS

Turns all dryer power and 

control circuits on and off. 

Provides protection to 

contactor coil only. Dryer 

MUST be externally fused 

with appropriate size fuse 

or circuit breaker (FLA x 

125% = fuse size).  See 

the following sheet for 

fuse size to be used for 

each dryer.

Provide protection for 

control and heater       cir-

cuits only! 

DO NOT

  use 

for ON/OFF control! If a 

breaker trips, determine 

the cause before resum-

ing operation.   

DOOR ADJUSTMENT

 

The dryer is equipped with adjustable doors located at each end of the 

oven chamber inside the fume hoods. The maximum opening is 6 inches 

(12” in the case of bottle dryers) and may be pulled down to belt  level 

on standard dryers (6” minimum opening on bottle dryers). Always run 

the doors as far closed as safely possible (typically allow 1-1/2” above 

product height) to contain the oven heat and help eliminate problems 

caused by air drafts in the shop. Exercise caution when adjusting the 

door height when the oven is hot, use a rag or wear a glove to prevent 

burning your fingers.

Содержание Thermatrol

Страница 1: ...ility of the HIX Corporation in the event of an obsolete part This warranty does not cover belts pads mug wraps canvas rubber blankets bulbs glass rod ends turn buckles on printers or damages due to accident misuse abuse alterations or damage due to neglect shipping or lack of proper lubrication or maintenance HIX shall not be responsible for repairs or alterations made by any person without the p...

Страница 2: ...f arrow on bottom of dryer B Match wire numbers of blower motor to flex conduit tan colored wires using orange wire nuts Polarity is not important Also attach the two green ground wires together 4 Duct Work A Run duct from the exhaust stack on the dryer to the outside of building Install a rain cap to prevent water damage to the dryer Maximum duct length 30 feet 9 meters from dryer to where it ex ...

Страница 3: ...ime the dryer is turned on 4 Function buttons detailed below RECIRCULATING AIR CONTROL The dryer is equipped with a very effective top delivery bottom recovery variable flow air recirculating system One zone is provided on models 24 and 36 belt models Two zones are provided on 48 models OPERATION TEMPERATURE CONTROL Not functional Will decrease setpoint SP when SP is displayed Will increase setpoi...

Страница 4: ...y get too hot and scorch the image closest to the heater Begin with items spaced at least 2 apart and 2 from side of dryer Thicker larger heavier items will require greater spacing APPLYING THE TRANSFER With some wraps including the HIX tool less Snap clasp wrap you will be able to image virtually top to bottom and handle to handle While full top to bottom and handle to handle imaging is possible ...

Страница 5: ...e to do so can cause fire personal injury or death 5 OPERATION least a away from the handle you should see consistent quality As you become more experienced there are tips and tricks that will make full wrap imaging more successful not fool proof but more consistent results can be achieved with proper preparation of the transfer Also quality mugs must be purchased while a mug wrap helps to cover s...

Страница 6: ...with wraps together This can cause small tears in your wrap leading to tearing of the wrap Only use on items the wrap is rated for the standard HMWII is de signed for both 11oz and 15oz mugs Use of these wraps for anything else may shorten the life of the wrap and could result in damage such as tearing For unusually sized or shaped items please utilize a wrap custom made for your application Sharp...