Assembly and Commissioning Instructions Servo amplifier D1-N
15.10.2015
117 / 183
CAUTION!
When inverting the I/O settings, a “controller enable” may be issued
and the motor may commutate and move in an uncontrolled manner. For
safety reasons, initial start-up should be performed with the motor plug dis-
connected to prevent accidents.
The “State” LED shows the current state of the input. Please check that all con-
nected inputs are functioning correctly when commissioning.
The “Set default” button resets all I/O settings to their default values.
Note: If the “Axis Enable” function is not used, this input must be inverted other-
wise a controller enable is not possible.
8.7.2
Outputs
The outputs of the D1-N are configured in the “Outputs” tab. The status of each
output is also shown in this tab. As with the inputs, inversion is also possible.
Clicking on the “Configure Ox” button opens a new window for function assign-
ment of the outputs.
Figure 8.76: “I/O center” – outputs