Care and replacement of glass: 

           Never strike the glass or slam door shut as such abuse can damage the glass and cause it to 
fail. Never operate your appliance with broken glass. Never attempt to clean glass when hot. Never 
clean glass with harsh abrasives. Replace glass only with ROBAX CERAMIC glass 254, 5mm x 
9”(228.6mm) x 15 9/16”(395.2mm), 354 5mm x 9”(228.6mm) x 17 7/16”(443mm)) available from your 
Hitzer dealer. Use of any other type of glass can cause glass to fail creating a fire hazard.  
           Should you be required to replace the glass first remove door from your stove and lay face 
down on a smooth solid surface. You will want to pad the surface especially if you have the optional 
plated door so as not to scratch the finish. Remove and save the glass retainers and screws. Carefully 
remove all broken glass and sealing gasket material. Install new glass using new sealing gasket 
material and reinstall all glass retainers and screws. 
 

End of season maintenance: 

  Moisture is your enemy. Summertime moisture and high humidity can be absorbed by dust and fly 
ash and cause rust and corrosion. A complete cleaning of the stove and venting system will help 
reduce this. Brush down all fly ash from the interior of the stove. Then you should vacuum out the fly 
ash from inside the stove including ledges and corners. Check outside painted surface of stove. If 
surface rust or blemishes are present lightly rub with fine steel wool to remove. You can then touch up 
the paint with high temperature stove paint available at your Hitzer dealer. 
  Next clean the venting system. Disconnect the chimney connector pipe and clean all fly ash from it 
especially elbows and horizontal runs.  It is not necessary to reinstall this pipe till you are ready to use 
the stove again in the fall. Have the chimney inspected and cleaned if necessary.  
   At the beginning of each heating season this appliance, the connector pipe, and chimney should be 
inspected to see that they are clear and in good working condition. 
    
 For  more  information  in  the  proper  installation  and  operation  of  your  quality  HITZER  heater  contact 
your local HITZER dealer. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание 254

Страница 1: ...FIRE FOLLOW THE INSTALLATION AND OPERATING INSTRUCTIONS FOLLOW THE INSTRUCTIONS WITHIN THIS MANUAL IF INSTRUCTIONS ARE NOT FOLLOWED A FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR EVEN DEATH HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS FOR USE OF SOLID FUEL COAL ONLY OTHER FUEL SOURCES CAN RESULT IN POISONOUS GAS EMISSION STOVE DAMAGE A...

Страница 2: ... STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY AND TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS CAREFULLY FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH CONTACT YOUR LOCAL BUILDING INSPECTOR OR FIRE OFFICIALS ABOUT THE NEED FOR A PERMIT RESTRICTIONS OR INSTALLATION INSPECTION REQUIRED IN YOUR AREA SAVE THE...

Страница 3: ...r damaged it is recommended to re line the chimney with a stainless steel liner Be sure the masonry chimney is compatible with the local building codes and requirements Factory Built System The factory built chimney must be a Class A High Temperature UL tested chimney UL 103 HT It is required for this Class A chimney to be listed and labeled under the UL standards If using an existing factory buil...

Страница 4: ...be a minimum of 7 inches in diameter The flue size for the model 254 should be a minimum of 6 inches in diameter Flue Size Continued The flue size also has a maximum size of inches in order to sustain the desired draft For an interior chimney the flue and chimney liner size cannot be larger than 3 times the square inches of the flue exhaust collar on the Hitzer stove For an exterior chimney that h...

Страница 5: ...E TO FOLLOW ALL CODES AND SAFETY REQUIREMENTS WHEN INSTALLING THE STOVE CAUTION THE USES OF ALUMINUM TYPE B GAS VENT FOR SOLID FUEL VENTING IS UNSAFE AND PROHIBITED BY THE NATIONAL FIRE PROTECTION ASSOCIATION CODE III INSTALLATION OF STOVE WARNING THE INSTALLATION OF THESE STOVES MUST COMPLY WITH STATE AND LOCAL REQUIREMENTS AND BE INSPECTED BY THE STATE OR LOCAL INSPECTOR IF REQUIRED NOTE THESE S...

Страница 6: ...per joint A manual or barometric damper is recommended to maintain a chimney draft between 03 to 06 inches of water inch wc Draft should never exceed 08 inch wc ...

Страница 7: ...ith required thickness T in inches R 1 k x T c C factor given R 1 C 2 Determine the R value of the proposed alternate floor protector a Use the formula in step 1 to convert values not expressed as R b For multiple layers add R values of each layer to determine the overall R value 3 If the overall R value of the system is greater than the R value of the specified floor protector the alternate is ac...

Страница 8: ...nd start adding coal Nut and or pea are the preferred sizes Add a thin layer approximately the thickness of the coal covering the entire grate area If the entire grate area is not covered the coal will not ignite Keep the draft controls open Once a layer has started to burn and turn red another layer can be added Another method for starting an Anthracite coal fire is by using self starting charcoa...

Страница 9: ...oes is maintain the firebox at a given temperature by adding more or less air There will be an initial trial and error period as you determine what stove temperature gives you the amount of heat you need in your house Once this setting is determined you should not have to change the setting unless there is a major change outside A good example of this is when we go from fall into the dead of winte...

Страница 10: ...e necessary to shake the grates morning and evening also Bituminous coal can have a tendency to fuse into clinkers The amount of clinkering is dependent on the grade of coal you are burning and the temperature you are burning at Before shaking you may have to break up ash clinkers with a poker Shake now until bits of red burning coal are dropping into the ash pan You can now reload with coal If fi...

Страница 11: ...ARTS OF YOUR STOVE WILL BE HOT ALWAYS WEAR GLOVES AND PROTECTIVE CLOTHING WHEN EMPTYING ASH PAN OR WORKING ON A HOT OR BURNING STOVE COAL STORAGE Storing your coal is quite simple Coal is not affected by insects rodents or moisture Bagged coal can be stacked anywhere that is convenient Bulk coal you will want to have a bin of some sort just so it doesn t spread all over Either bulk or bagged it ca...

Страница 12: ...nance Moisture is your enemy Summertime moisture and high humidity can be absorbed by dust and fly ash and cause rust and corrosion A complete cleaning of the stove and venting system will help reduce this Brush down all fly ash from the interior of the stove Then you should vacuum out the fly ash from inside the stove including ledges and corners Check outside painted surface of stove If surface ...

Страница 13: ...e manufactured by Hitzer Inc said original purchaser shall send said defective part to the aforementioned offices of Hitzer Inc for determination therewith to be made by Hitzer Inc Hitzer Inc should it determine that said component was defective shall thereafter replace said component at no cost to the original purchaser All shipping charges shall be the responsibility of the original purchaser an...

Страница 14: ... original purchaser must pay shipping to and from Hitzer Inc 269 E Main St Berne In 46711 In order for the above stated limited warranty to be effective and binding upon Hitzer Inc this portion herein must be detached and sent by the original owner to Hitzer Inc at the above stated address within ten 10 days from the date of purchase of said stove Owner s Name __________________________ Address __...

Отзывы: