■ Precautions for Use 

- Do not disconnect the cable during use. 

- Do not disconnect the product from the socket during use. 

- Do not apply high impact to the product. 

 

■ Precautions for Wiring 

- Make sure to wire contacts correctly. (Refer to Wiring) 

- Wire and supply the power to the product after checking the specifications. 

- Incorrect power voltage may cause damage to the product. 

- Pay attention to prevent electric shock. 

 

■ Disposal of Product 

- Make sure to separate the PCB and main unit from housing before disposing the products. 

No part (ex. Mercury Switch) has influence on the environment, so no special attention is 

required. 

  Remove it with the power disconnected. 

  Remove  in  reverse  order  of  installation.  (Power  off 

  Release  the  Locker 

  Body 

Disconnection 

 Wiring Disconnection 

 Socket Disconnection) 

  It is recommended to use washers to prevent a loosening when the product is fixed 

using bolts. 

  Wiring shall be performed after checking of wiring diagram described in the manual or sticker. 

  Make sure that the power source whether it is AC 110V, AC 220V, or DC +24V. 

 It is recommended to use AWG 13 or 14 cable between the controller and level sensor, and 

use shield cable in case that the distance between the controller and level sensor is quite long 

(several hundred meters ~ 500m) and for low conductivity medium. (Non-recommendation 

cables may result in some differences in operating and level sensing distances.) 

  Check the LED color after applying of power. (High: Red, Low: Green) 

  Power shall be applied after completing of installation. 

■ Relay contact does not work 

- Check whether the LED lamp is on/off. 

- Check the cable connection. 

- Check the input voltage. 

- Check the connection between the body and the socket. 

- Check the level sensor wiring cable. 

 

Содержание HLC-200A

Страница 1: ...ICE FACTORY R D INSTITUDE HITROL CO LTD 141 Palhakgol gil Jori eup Paju si Gyeonggi do Korea TEL 82 31 950 9700 FAX 82 31 943 5600 www hitrol com INSTRUCTION MANUAL LEVEL CONTROLLER ALARM UNIT HLC 200...

Страница 2: ...o carry outthework Table of Contents Overview 3 Characteristics 3 Operating Principle and Composition 3 Specifications 4 HLC 200A 4 HLC 200F 4 Dimensions 4 Installation and Wiring 5 Installation 5 HLC...

Страница 3: ...ructure type for freely detachment Operating can be checked through LED lamp High Red Low Green Sensitivity can be adjusted at the site if the sensor is too much sensitive to the conductivity or foam...

Страница 4: ...0 Power Source AC 110V or 220V 50 60Hz DC 24V DC 21V DC 30V Standby Power Consumption AC 110V 0 5W AC 220V 0 8W DC 24V 0 48W Active Power Consumption AC 110V 1 4W AC 220V 2W DC 24V 1 1W Output Voltage...

Страница 5: ...allation and Wiring Control Drain Pump LED Color Red Green Input 1 3 4 1 3 4 Output 8 5 8 6 Alarm H A L A LED Color Red Green Input 1 4 1 4 Output 8 5 8 6 1 Install the socket DIN Rail 2 Fix it using...

Страница 6: ...HLC 200 Series HITROL CO LTD 6 HLC 200F Wiring Control Drain Pump LED Color Red Green Input 1 3 4 1 3 4 Output 8 5 8 6 Alarm H A L A LED Color Red Green Input 1 4 1 4 Output 8 5 8 6 Connection Diagram...

Страница 7: ...the liquid is not detected Sensitivity Dial It is a function to adjust the sensitivity in condition that it is too sensitive to the conductivity of the medium or foam Turning counter clockwise is for...

Страница 8: ...Power off Release the Locker Body Disconnection Wiring Disconnection Socket Disconnection It is recommended to use washers to prevent a loosening when the product is fixed using bolts Wiring shall be...

Страница 9: ...mber and matters regarding input output The serial number is a unique manufacturing number for the identification of products Controller is normal but not working 1 Electrode Type Level Switch If ther...