HITROL HLC-200A Скачать руководство пользователя страница 5

HLC-200 Series 

HITROL CO., LTD.                                             

          5

 

HLC-200 Series 

 

Installation 

 

HLC-200A Wiring 

The image above is from HLC-200A. 

 

Installation 
and Wiring 

 

 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Control 

Drain 

Pump 

LED Color 

Red 

Green 

Input 

1, 3, 4 

1, 3, 4 

Output 

8, 5 

8, 6 

Alarm 

H. A 

L. A 

LED Color 

Red 

Green 

Input 

1, 4 

1, 4 

Output 

8, 5 

8, 6 

(1) Install the socket DIN Rail                                  (2) Fix it using bolts 

- After assembling the HLC-200 Series body on the socket, lift the locker to fix the body. 

Connection Diagram 

Содержание HLC-200A

Страница 1: ...ICE FACTORY R D INSTITUDE HITROL CO LTD 141 Palhakgol gil Jori eup Paju si Gyeonggi do Korea TEL 82 31 950 9700 FAX 82 31 943 5600 www hitrol com INSTRUCTION MANUAL LEVEL CONTROLLER ALARM UNIT HLC 200...

Страница 2: ...o carry outthework Table of Contents Overview 3 Characteristics 3 Operating Principle and Composition 3 Specifications 4 HLC 200A 4 HLC 200F 4 Dimensions 4 Installation and Wiring 5 Installation 5 HLC...

Страница 3: ...ructure type for freely detachment Operating can be checked through LED lamp High Red Low Green Sensitivity can be adjusted at the site if the sensor is too much sensitive to the conductivity or foam...

Страница 4: ...0 Power Source AC 110V or 220V 50 60Hz DC 24V DC 21V DC 30V Standby Power Consumption AC 110V 0 5W AC 220V 0 8W DC 24V 0 48W Active Power Consumption AC 110V 1 4W AC 220V 2W DC 24V 1 1W Output Voltage...

Страница 5: ...allation and Wiring Control Drain Pump LED Color Red Green Input 1 3 4 1 3 4 Output 8 5 8 6 Alarm H A L A LED Color Red Green Input 1 4 1 4 Output 8 5 8 6 1 Install the socket DIN Rail 2 Fix it using...

Страница 6: ...HLC 200 Series HITROL CO LTD 6 HLC 200F Wiring Control Drain Pump LED Color Red Green Input 1 3 4 1 3 4 Output 8 5 8 6 Alarm H A L A LED Color Red Green Input 1 4 1 4 Output 8 5 8 6 Connection Diagram...

Страница 7: ...the liquid is not detected Sensitivity Dial It is a function to adjust the sensitivity in condition that it is too sensitive to the conductivity of the medium or foam Turning counter clockwise is for...

Страница 8: ...Power off Release the Locker Body Disconnection Wiring Disconnection Socket Disconnection It is recommended to use washers to prevent a loosening when the product is fixed using bolts Wiring shall be...

Страница 9: ...mber and matters regarding input output The serial number is a unique manufacturing number for the identification of products Controller is normal but not working 1 Electrode Type Level Switch If ther...