CONFIDENTIAL 60
Chapter 7: Error Message
Error Message
RED LED
blinking
times
Possible Cause
Solution
Ribbon Missing
1
1. Chip of ribbon cartridge is contaminated,
or poor contact.
2. Door/Ribbon Cassette Sensor is NG.
3. Poor contact between sensor and chip.
4. Main Board is NG.
1.Clean chip of ribbon cartridge.
2.Change Door Sensor/Ribbon
Cassette Sensor.
3.Change ribbon cartridge.
4.Change Main Board.
Unsupport Ribbon
2 + 3
1. The ribbon cartridge is not for this region.
2. Smart Chip Sensor is contaminated.
3. Smart Chip Sensor is NG.
4. Main Board is NG.
1.Change ribbon cartridge.
2.Clean Smart Chip Sensor.
3.Change Smart Chip Sensor.
4.Change Main Board.
Ribbon Out
3
1. Ribbon LED & Ribbon Sensor are
contaminated.
2. Voltage of Ribbon LED & Ribbon Sensor
is incorrect.
3. Main Board is NG.
1.Clean Ribbon LED & Ribbon
Sensor.
2.
Adjust/Calibrate Ribbon Sensor
Voltage
3.Change Ribbon LED.
4.Change Ribbon Sensor.
5.Change Main BD.
Paper Out
4
1. Pick-Up Roller is contaminated.
2. Lifter is NG.
3. Guide_Cassette is NG.
4. CAM Motor is NG.
5. Main Board is NG.
1.Clean Pick-Up Roller.
2.Change Lifter.
3.Change Guide_Cassette.
4.Change CAM Motor.
5.Change Main Board.
Paper Jam
5
1. LE Sensor & Jam Sensor are
contaminated.
2. LE Sensor is NG.
3. Jam Sensor is NG.
4. Guide_Paper is NG.
5. Separator_Paper is NG.
6. Capstan Motor is NG.
7. Main Board is NG.
1.Clean Leading Edge Senor & Jam
Sensor.
2.Change Leading Edge Sensor.
3.Change Jam Sensor.
4.Change Guide_Paper.
5.Change Separator_Paper.
6.Change Capstan Motor.
7.Change Main Board.
Paper mismatch
6
1. Paper type incorrect
2. LE Sensor & Jam Sensor are
contaminated.
3. LE Sensor is NG.
4. Jam Sensor is NG.
5. Main Board is NG.
1. Check the paper type.
2. Clean Leading Edge Senor & Jam
Sensor.
3. Change Leading Edge Sensor.
4. Change Jam Sensor.
5. Change Main Board.
CAM Error
8
1. CAM Sensor is contaminated.
2. CAM Sensor is NG.
3. CAM Motor is NG.
4. Main Board is NG.
1.Clean CAM Sensor.
2.Change CAM Sensor.
3.Change CAM Motor.
4.Change Main Board.
NAND Flash Error
9
Main Board is NG.
Change Main Board.
Ribbon IC Error
10
Chip of ribbon cartridge is NG.
1.Clean chip of ribbon cartridge.
2.Change ribbon cartridge.
ADC Error
12
1. TPH cable is not securely connected to
Main Board.
2. TPH is NG.
3. Main Board is NG.
1.Re-connect TPH cable.
2.Change TPH.
3.Change Main Board.
FW Checksum Error
13
1. FW itself or its region is incorrect.
2. Main Board is NG.
1.Re-update FW (make sure region is
correct).
2.Change Main Board.
SRAM Error
14
Main Board is NG.
Change Main Board.
Содержание P110S
Страница 1: ...CONFIDENTIAL 1 P110S Service Guide Version 1 11 ...
Страница 11: ...CONFIDENTIAL 11 Mechanism Movements User Interface ...
Страница 12: ...CONFIDENTIAL 12 ...
Страница 13: ...CONFIDENTIAL 13 ...
Страница 18: ...CONFIDENTIAL 18 Printing P4 Lifter is down Roller_Pick Up is disable TQL_Take is enable Paper path ...