CONFIDENTIAL 51
Maintenance Parts Replacement Procedures
Parts Name MTR PM 3.75 7OHM BIP P110S ROHS
Parts No.
17.MAP25.BM1
Tools
Screwdriver
Procedure No.
Maintenance part: MTR PM 3.75 7OHM BIP P110S ROHS (CAPSTAN MOTOR)
[Step 1] Remove the ASSY_CASE_LEFT, ASM_ID_CASE_RIGHT and CHASSIS ASSY according
to the
Procedure No. 1
.
[Step 2] Remove connector of MTR PM 3.75 7OHM BIP P110S ROHS that connects with MAIN BD
then remove 3 screws.
[Step 3] Remove E-ring then then take arm-swing out from the right side.